{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3316-6BA","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3316-6BA","canonicalUrl":"https://aoctrl.com/siemens/5SV3316-6BA","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3316-6BA","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3 series RCCB, 2-pole, 63 A rated, 30 mA Type A, 230 V AC, 10 kA SCCR, DIN rail mount, 36 mm wide.","salesMarkdown":"Type A means it catches both sinusoidal AC ground faults and pulsating DC faults, which is what you need on variable-speed drives, washing machines, or any load with rectified current. The 30 mA trip threshold is the standard for personal protection against lethal shock. Rated 230 V AC, it handles residential and light commercial single-phase supplies. ## Thermal derating — the real-world current limit That's unusual — most breakers start derating at 40 °C. At 65 °C it drops to 56.96 A, and at 70 °C to 48.19 A. If your panel sits near a hot motor or a sunny wall, the 63 A nameplate holds until you cross 60 °C. Mounts on DIN rail (REG), 36 mm wide — that's 2 width units. Depth is 70 mm, same as the installation depth, so it sits flush with other SENTRON modular devices. That's a wide range: 0.75 mm² is fine for control wiring, 35 mm² handles the full 63 A load without needing a reducer. Supply can come from top or bottom.","metaTitle":"Siemens 5SV3316-6BA SENTRON RCCB, 63A 30mA Type A, 2-Pole","metaDescription":"Siemens 5SV3316-6BA SENTRON RCCB, 63A rated, 30mA Type A fault current, 2-pole, 10kA SCCR. DIN rail mount, 36mm wide. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Solid":"0.75 ... 35 mm²","Width":"36 mm","title":"5SV3316-6BA","Height":"90 mm","Stranded":"0.75 ... 35 mm²","at 40 Cel":"63 A","at 45 Cel":"63 A","at 50 Cel":"63 A","at 55 Cel":"63 A","at 60 Cel":"63 A","at 65 Cel":"56.96 A","at 70 Cel":"48.19 A","Rated Value":"50 Hz","description":"Residual current operated circuit breaker, 2-pole, type A, In: 63 A, 30 mA, Un AC: 230 V","Mounting type":"DIN rail (REG)","During Storage":"-40 ... +75 °C","Number of poles":"2","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +45 °C","Product designation":"RCCB","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Number of width units":"2","Type of fault current":"A","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","I2t-value / permissible":"110 000 A²·s","circuit-breaker / Design":"5SV3","Short-circuit current rating":"10 kA","Current / at AC / rated value":"63 A","Product feature / silicon-free":"Yes","Position / of power supply cord":"top or bottom","Protection against electrical shock":"Finger and back-of-hand safe","Supply voltage / at AC / rated value":"230 V","Surge current resistance / rated value":"1 kA","Switching function / short-term delayed":"No","Tripping residual current / rated value":"30 mA","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Size of installation devices / acc. to DIN 43880":"1","Supply voltage / for testing equipment / minimum":"195 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/61eb07fb5ac0a09a60bfecbf9c7d40bc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=603982&mlfb=5SV3316-6BA"},"ai":{"faq":[{"question":"What is the 5SV3316-6BA used for?","answer":"It's a residual current circuit breaker (RCCB) for personal protection against electric shock. The 30 mA Type A trip catches both AC and pulsating DC ground faults, so it's specified on circuits feeding variable-speed drives, pumps, conveyors, or any equipment with rectified power."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3316-6BA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3316-6BA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}