{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3316-6KL","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3316-6KL","canonicalUrl":"https://aoctrl.com/siemens/5SV3316-6KL","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3316-6KL","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3316-6KL, 2-pole RCCB, type A, 63 A rated current, 30 mA residual sensitivity, 230 V AC, N left, DIN rail mount.","salesMarkdown":"The N-left configuration means the neutral conductor connects on the left side of the device, which matters for panel layout consistency. The 63 A rating covers the main feeder or sub-feed in a distribution board, sized for high-load circuits like electric ranges, large water heaters, or sub-panel feeds. The 30 mA trip threshold is the IEC touch-protection standard — it clears ground faults before they reach a level that can cause ventricular fibrillation. On a 50 Hz system only (not 50/60 Hz dual-rated), so verify frequency compatibility if the installation is on a 60 Hz supply. The 70 mm depth is a standard RCCB depth — it sits flush with the DIN rail and leaves clearance for wiring gutters in a typical 120 mm deep enclosure. Mounting position is unrestricted, and power can be supplied from top or bottom, which simplifies busbar and cable routing.","metaTitle":"Siemens 5SV3316-6KL SENTRON RCCB, 2-Pole, 63 A, 30 mA, 230 V","metaDescription":"Siemens 5SV3316-6KL SENTRON residual current circuit breaker (RCCB), 2-pole, type A, 63 A, 30 mA, 230 V AC. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3316-6KL","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, In: 63 A, 30 mA, Un AC: 230 V, N left","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"N left","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"230 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"195 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"80 A","for rated value of the current at AC in hot operating state per pole":"5.3 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aa645e0c9f0082d6e0497d30164913ae.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=143326&mlfb=5SV3316-6KL"},"ai":{"faq":[{"question":"Where can I buy 5SV3316-6KL?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will 5SV3316-6KL drop into a panel specified around 5SL4363-7 without rewiring?","answer":"No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) with a 54 mm width (3 modular units), while the 5SV3316-6KL is a 2-pole RCCB at 36 mm (2 units). The different function (overcurrent vs. ground-fault protection) and footprint mean a panel designed for the MCB would need rewiring and a different busbar arrangement to accept the RCCB."},{"question":"What compliance documentation does Siemens provide for 5SV3316-6KL?","answer":"The part carries a CE marking per the Low Voltage Directive and is designed to IEC 61008-1. RoHS and REACH compliance documentation is standard for SENTRON products, though the specific declaration is not included in this listing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3316-6KL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3316-6KL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}