{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3317-6KK01","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3317-6KK01","canonicalUrl":"https://aoctrl.com/siemens/5SV3317-6KK01","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3317-6KK01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 80 A, 30 mA, Type A, short-time delayed, 2-pole, 36 mm, DIN rail.","salesMarkdown":"Type A means it responds to AC residual currents plus pulsed DC, covering modern electronics with half-wave rectification. Short-time delayed design means it holds through transient leakage pulses up to 3 kA surge current without nuisance tripping, which is critical when feeding downstream equipment with capacitive inrush or surge suppressors. No end-of-life notice or successor has been published. If you're freezing a BOM, this is a safe line-item with no imminent LTB risk. Silicon-free construction is noted for applications where silicone outgassing can contaminate contacts or optics. Above that, derate: 77.87 A at 45 °C, 74.77 A at 50 °C, 70.26 A at 55 °C, 64.32 A at 60 °C, 56.96 A at 65 °C, and 48.2 A at 70 °C (–). Short-circuit current rating is 10 kA per IEC 61008-1 and 0.8 kA per EN 60898 — the EN figure governs domestic consumer-unit coordination; the 10 kA figure applies in industrial distribution boards with higher fault capacity. Let-through energy is rated at 110,000 A²·s, and the permissible let-through current is 7,100 A — useful for selectivity calculations with downstream MCBs.","metaTitle":"Siemens SENTRON 5SV3317-6KK01 RCCB 80A 30mA Type A, 2-pole","metaDescription":"Siemens SENTRON 5SV3317-6KK01 RCCB, 80A rated, 30mA trip, Type A, short-time delayed, 2-pole, 36mm wide, DIN rail. Current production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"50/60 Hz","Product Designation":"RCCB","at AC / rated value":"80 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed","Residual Current Type":"A","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"80 A","at 45 °C / rated value":"77.87 A","at 50 °C / rated value":"74.77 A","at 55 °C / rated value":"70.26 A","at 60 °C / rated value":"64.32 A","at 65 °C / rated value":"56.96 A","at 70 °C / rated value":"48.2 A","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","acc. to EN 60898 / rated value":"0.8 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Current Resistance / Rated Value":"3 kA","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"Yes","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bfbae0b24ba9e00d7ef77b70227ddbf6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604171&mlfb=5SV3317-6KK01","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3317-6KK01/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV3317-6KK01 and how is it quoted?","answer":"It is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"What are the key ratings of 5SV3317-6KK01?","answer":"80 A rated current, 30 mA residual trip, Type A, short-time delayed, 2-pole, 36 mm wide, DIN rail mount, 10 kA SCCR per IEC 61008-1."},{"question":"Will 5SV3317-6KK01 drop into a panel wired for 5SL6550-7BB?","answer":"Both are 2-pole RCCBs on a 36 mm DIN-rail footprint, so the mechanical fit is the same. But 5SV3317-6KK01 is 80 A / 30 mA Type A short-time delayed; the 5SL6550-7BB is a different rating. Verify the existing circuit's load and fault requirements before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3317-6KK01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3317-6KK01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}