{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3322-6KK60","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3322-6KK60","canonicalUrl":"https://aoctrl.com/siemens/5SV3322-6KK60","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3322-6KK60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3322-6KK60 RCCB, 2-pole, Type A, In: 25 A, 30 mA, 6 mA DC, Un AC: 230 V, Electro Mobility, short-time delayed, 4 MW, DIN rail.","salesMarkdown":"The Siemens SENTRON 5SV3322-6KK60 is a 2-pole residual current operated circuit breaker (RCCB) rated 25 A, 30 mA residual sensitivity, Type A, with an additional 6 mA DC detection path — the SIGRES variant. It's designed for electro-mobility (EV charging) circuits where smooth DC leakage currents can blind standard Type A devices. The short-time delayed characteristic (S-type) prevents nuisance tripping from transient surges or inrush currents typical of EV supply equipment. The 6 mA DC SIGRES function detects smooth DC fault currents up to 6 mA — enough to catch the leakage from a rectifier stage in an EV charger before it desensitises a standard Type A device. The short-circuit withstand rating is 10 kA per IEC 61008-1, with a conditional short-circuit current of 0.8 kA (the IΔn rating for the RCD function). The series fuse maximum permissible is 100 A, so upstream protection must be coordinated. ## Where it goes — panel and environment The 60 mm grid spacing matches standard distribution-board pitch. Ambient range -25 °C to 45 °C operating, -40 °C storage. Supply voltage for the test circuit is 70–250 V AC, 50/60 Hz.","metaTitle":"Siemens 5SV3322-6KK60 SENTRON RCCB, 2-pole, 25A, 30mA, Type","metaDescription":"Siemens SENTRON 5SV3322-6KK60 RCCB, 2-pole, Type A, 25A, 30mA, 6mA DC, 230V AC, short-time delayed. Active production, sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"SIGRES, 6mA DC","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom (top for SIGRES function also in switched-off state)","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"Yes","Value Range Of The Operating Frequency":"50/60 Hz","value range of the supply voltage at AC":"70-250 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50/60 Hz","Supply Voltage For Testing Equipment Minimum":"70 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"100 A","for rated value of the current at AC in hot operating state per pole":"1.2 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/450d5ed5e5d0fa82891bc193fb4bb010.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1499751&mlfb=5SV3322-6KK60","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3322-6KK60/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV3322-6KK60 and what is the price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."},{"question":"What compliance documentation does Siemens provide for 5SV3322-6KK60?","answer":"The part carries IEC 61008-1 certification (the governing standard for RCCBs). RoHS and REACH compliance is standard for Siemens SENTRON products; specific declarations are available on request."},{"question":"Will 5SV3322-6KK60 drop into a panel specified around 5SL4363-7 without rewiring?","answer":"No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) on a 54 mm wide footprint, while the 5SV3322-6KK60 is a 2-pole RCCB at 72 mm wide. Different function, different wiring, different busbar pitch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3322-6KK60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3322-6KK60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}