{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3324-3KK60","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3324-3KK60","canonicalUrl":"https://aoctrl.com/siemens/5SV3324-3KK60","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3324-3KK60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 2-pole, Type F, In: 40A, 30mA, 6mA DC, Un AC: 230V, Electro Mobility, short-time delayed, DIN rail mount, IP20.","salesMarkdown":"## What this RCCB is and why it matters for EV charging It's a 2-pole, Type F device rated 40 A with 30 mA residual sensitivity — but the key differentiator is the integrated 6 mA DC SIGRES function, which detects smooth DC fault currents that standard AC/Type A RCCBs miss. That matters because modern EV chargers and inverters can inject DC ripple into the protective earth, blinding a conventional RCD. This unit handles it without nuisance tripping. Rated for 230 V AC at 50/60 Hz, with a short-circuit withstand of 10 kA per IEC 61008-1, it's sized for residential and light commercial charging infrastructure where fault currents stay under that threshold. The short-time delayed design (Type F inherently includes a delay) allows selectivity with downstream 10 ms RCDs, so a fault on a single socket doesn't kill the whole board. Depth is 70 mm, matching the standard installation depth for SENTRON distribution boards. IP20 with conductors connected — fine inside a closed distribution board; not for open wet locations.","metaTitle":"Siemens 5SV3324-3KK60 SENTRON RCCB Type F, 40A 30mA, 6mA DC","metaDescription":"Siemens 5SV3324-3KK60 SENTRON 2-pole RCCB, Type F, 40A, 30mA, 6mA DC SIGRES, 10 kA SCCR, short-time delayed. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"SIGRES, 6mA DC","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom (top for SIGRES function also in switched-off state)","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"Yes","Value Range Of The Operating Frequency":"50/60 Hz","value range of the supply voltage at AC":"70-250 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50/60 Hz","Supply Voltage For Testing Equipment Minimum":"70 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"100 A","for rated value of the current at AC in hot operating state per pole":"2.5 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7b84206b8399091da4c2468106198664.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1499752&mlfb=5SV3324-3KK60","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3324-3KK60/alternatives.json"},"ai":{"faq":[{"question":"What is the 6 mA DC SIGRES function on this RCCB?","answer":"The SIGRES 6 mA DC detection means this RCCB can sense smooth DC fault currents as low as 6 mA, which is critical for EV charging stations where inverters can produce DC residual currents that would blind a standard Type A RCD. It prevents the device from being desensitized by DC components."},{"question":"Where can I buy 5SV3324-3KK60 and how is it quoted?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume and delivery needs."},{"question":"What is the difference between this Type F RCCB and a standard Type A?","answer":"Type F (per IEC 62423) adds detection of composite residual currents up to 10 kHz and smooth DC currents — exactly what you get from variable-speed drives and EV chargers. A Type A would trip on the AC component but may fail to detect the DC ripple that can saturate its sensing coil. This unit also includes the 6 mA DC SIGRES for pure DC faults."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3324-3KK60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3324-3KK60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}