{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3346-6KK60","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3346-6KK60","canonicalUrl":"https://aoctrl.com/siemens/5SV3346-6KK60","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3346-6KK60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 4-pole, Type A, In: 63A, 30mA, 6mA DC, Un AC: 400V, Electro Mobility, short-time delayed, 10 kA SCCR.","salesMarkdown":"The Siemens 5SV3346-6KK60 is a 4-pole residual current circuit breaker (RCCB) from the SENTRON family, rated 63 A at 400 V AC with a 30 mA trip sensitivity and Type A waveform recognition that also detects pulsating DC fault currents up to 6 mA DC. The short-time delayed design (SIGRES function) means it tolerates brief surge currents without nuisance tripping — important on circuits with electronic loads or inrush-heavy equipment. Snaps onto DIN rail (REG) and occupies 4 modular width units at 60 mm grid spacing. Depth is 70 mm, width 72 mm, height 90 mm. Listed as Active by Siemens — this is a current-production catalog item, not a phase-out or NRND line. No successor has been issued because none is needed. The 63 A rating at 400 V AC covers most three-phase distribution subfeeds and large single-phase loads. The 30 mA trip threshold is the standard for personnel protection (shock hazard) in residential and commercial panels. Type A detection means it catches sinusoidal AC faults plus pulsating DC — essential on circuits with rectifiers, variable-speed drives, or EV charging equipment (the Electro Mobility designation confirms suitability for electric-vehicle supply equipment). The short-time delayed characteristic (SIGRES) prevents tripping on transient surges like capacitor switching or motor starting, so it coordinates downstream without nuisance opens.","metaTitle":"Siemens 5SV3346-6KK60 SENTRON RCCB, 4P, 63A, 30mA, Type A","metaDescription":"Siemens SENTRON 5SV3346-6KK60 RCCB, 4-pole, Type A, 63A, 30mA, 400V AC. Short-time delayed, 10kA SCCR. Active production, available to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","title":"5SV3346-6KK60","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 4-pole, Type A, In: 63A, 30mA, 6mA DC, Un AC: 400V, Electro Mobility","Grid Spacing":"60 mm","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom (top for SIGRES function also in switched-off state)","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"Yes","Value Range Of The Operating Frequency":"50/60 Hz","value range of the supply voltage at AC":"70-440 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","Supply Voltage For Testing Equipment Minimum":"70 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"100 A","for rated value of the current at AC in hot operating state per pole":"5 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2f9e83eb169179ddd4428d6075f216bf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1499765&mlfb=5SV3346-6KK60"},"ai":{"faq":[{"question":"Where can I buy 5SV3346-6KK60?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation is available for 5SV3346-6KK60?","answer":"The RCCB is designed to IEC 61008-1 (the rated conditional short-circuit current of 0.8 kA per that standard is listed). As a SENTRON product, it carries CE marking and is manufactured under Siemens' quality system. Specific RoHS/REACH declarations and the full IEC test certificate are available from Siemens upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3346-6KK60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3346-6KK60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}