{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3352-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3352-6","canonicalUrl":"https://aoctrl.com/siemens/5SV3352-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3352-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3352-6, 4-pole Type A RCCB, In 25 A, 30 mA, Un AC 500 V, instantaneous, DIN rail mount, IP20.","salesMarkdown":"The Siemens 5SV3352-6 is a SENTRON 4-pole residual current circuit breaker (RCCB), Type A, rated 25 A with 30 mA sensitivity at 500 V AC. Snaps onto DIN rail (REG profile) and occupies 4 modular width units at 60 mm grid spacing. Mounting position is unrestricted — horizontal, vertical, or upside-down — which helps when fitting into a crowded enclosure. The 70 mm installation depth matches the standard SENTRON modular range, so it sits flush with adjacent MCBs and RCBOs on the same rail. Type A detection covers sinusoidal AC residual currents plus pulsating DC — the kind produced by single-phase rectifiers in washing machines, LED drivers, and small VFDs. Rated for ambient temperatures from -25 °C to +45 °C operating, with storage down to -40 °C. Silicon-free construction — relevant for automotive or paint-shop environments where silicone outgassing can cause adhesion failures. IP20 protection applies once installed in a distribution board with conductors connected; the device itself is not rated for wet or dusty locations without an enclosure. Overvoltage category III, suitable for fixed installation downstream of the utility meter.","metaTitle":"Siemens 5SV3352-6 SENTRON RCCB, 4-pole Type A, 25 A, 30 mA,","metaDescription":"Siemens 5SV3352-6 SENTRON 4-pole Type A RCCB, 25 A rated current, 30 mA sensitivity, 500 V AC, 10 kA SCCR. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"500 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"195 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"0.8 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bbf3928cfac16c93f4af913ec4a716dd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=675866&mlfb=5SV3352-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3352-6/alternatives.json"},"ai":{"faq":[{"question":"What is the 5SV3352-6 used for?","answer":"It's a 4-pole Type A RCCB used for earth leakage protection in three-phase distribution boards, rated 25 A and 30 mA sensitivity at 500 V AC."},{"question":"Will the 5SV3352-6 drop into a panel specified around the 5SL4363-7?","answer":"No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) with a different function and a 54 mm width, while the 5SV3352-6 is a 4-pole RCCB at 72 mm wide. They serve different roles in the panel and are not direct drop-in replacements."},{"question":"Where can I buy the 5SV3352-6?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3352-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3352-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}