{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3354-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3354-6","canonicalUrl":"https://aoctrl.com/siemens/5SV3354-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3354-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3354-6 RCCB, 4-pole, Type A, 40 A, 30 mA, 10 kA, DIN rail, 4 MW.","salesMarkdown":"The 70 mm depth keeps it flush with adjacent breakers in a typical panel layout. The 30 mA trip threshold covers personnel protection (hand-to-hand or hand-to-ground fault paths) per IEC 61008-1. Type A detection handles pulsating DC residual currents from single-phase rectifiers (common in washing machines, LED drivers, EV chargers) plus sinusoidal AC — so it's the standard choice for mixed-load residential and light commercial panels. The 10 kA short-circuit current rating (SCCR) means the device safely interrupts faults up to that level without welding contacts or cascading upstream; the let-through current is limited to 5 200 A, and the I²t withstand is 58 000 A²·s — both figures matter for coordination with the upstream MCB or fuse.","metaTitle":"Siemens SENTRON 5SV3354-6 RCCB, 40 A, 30 mA, Type A, 4P","metaDescription":"Siemens SENTRON 5SV3354-6 RCCB, 40 A rated, 30 mA trip, Type A, 4-pole, 10 kA SCCR, DIN rail mount. Current production. Sourced to order; confirm availability and price via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"40 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","I2t value permissible":"58 000 A²·s","Residual Current Type":"A","at 40 °C rated value":"40 A","at 45 °C rated value":"40 A","at 50 °C rated value":"40 A","at 55 °C rated value":"40 A","at 60 °C rated value":"40 A","at 65 °C rated value":"40 A","at 70 °C rated value":"40 A","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom","Let-Through Current Permissible":"5 200 A","Tripping Fault Current Rated Value":"30 mA","Surge Current Resistance Rated Value":"1 kA","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"500 V","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"195 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"1.8 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b7e3ea0fb24eb76878e4425cd057fdda.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=675867&mlfb=5SV3354-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3354-6/alternatives.json"},"ai":{"faq":[{"question":"What is 5SV3354-6's listed depth (70 mm) on this component line?","answer":"The depth is 70 mm, which is the standard depth for SENTRON RCCBs and matches the 70 mm installation depth listed."},{"question":"What is 5SV3354-6's listed width (72 mm) on this component line?","answer":"The width is 72 mm, corresponding to 4 modular width units on a 60 mm grid DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3354-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3354-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}