{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3356-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3356-6","canonicalUrl":"https://aoctrl.com/siemens/5SV3356-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3356-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 4-pole, type A, In: 63 A, 30 mA, Un AC: 500 V, 10 kA SCCR, DIN rail mount, 4 MW.","salesMarkdown":"The Siemens SENTRON 5SV3356-6 is a 4-pole residual current circuit breaker (RCCB), type A, rated 63 A with 30 mA sensitivity at 500 V AC. It's an instantaneous-trip device — no intentional delay, so it clears earth faults as fast as the fault current drives it. Overvoltage category III puts it on the load side of the main distribution board, not at the service entrance. ## Fit and panel integration Depth is 70 mm, matching the standard installation depth for SENTRON distribution boards. The IP20 rating applies only with the distribution board installed and conductors connected — this is a panel-internal device, not a standalone enclosure. Supply can land top or bottom; mounting position is unrestricted. Silicon-free construction matters for automotive and painting-line panels where silicone outgassing can cause coating defects.","metaTitle":"Siemens 5SV3356-6 SENTRON RCCB, 4P Type A, 63A 30mA 500V","metaDescription":"Siemens SENTRON 5SV3356-6 RCCB, 4-pole type A, 63 A, 30 mA, 500 V AC, 10 kA SCCR. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"500 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"195 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"3.9 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c7c97afbfecb5d6917ce0b6ebcba7b53.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=675868&mlfb=5SV3356-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3356-6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3356-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3356-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}