{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3412-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3412-6","canonicalUrl":"https://aoctrl.com/siemens/5SV3412-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3412-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3412-6, RCCB, 2-pole, Type A, 25 A, 100 mA, 230/400 V AC, 10 kA, DIN rail, IP20.","salesMarkdown":"The 5SV3412-6: The 100 mA trip and Type A residual current detection mean this RCCB is suited for circuits with pulsed DC fault currents from single-phase rectified loads — common in washing machines, LED drivers, and IT equipment. It is not a G-type (short-time delayed) device; the switching function is instantaneous with no intentional delay, so it trips immediately on fault. The 25 A rating holds across the full 40 °C to 60 °C ambient range without derating (–); at 65 °C it derates to 23.3 A, and at 70 °C to 17.6 A (–). For a panel that sees sustained high ambient temperatures, the 25 A nominal gives roughly 2 A of headroom before derating starts at 65 °C. The let-through current is limited to 5 200 A, and the permissible I²t is 58 000 A²·s, which helps with downstream coordination. Depth is 70 mm, height 90 mm. Installation depth matches the depth dimension. IP20 rating applies once the distribution board is installed with conductors connected — meaning it is not touch-protected on the busbar side until the enclosure cover is on. Silicon-free construction is specified — relevant for paint-shop or potting applications where silicone outgassing can cause adhesion failures.","metaTitle":"Siemens SENTRON 5SV3412-6 RCCB, 25 A, 100 mA, Type A, 2-Pole","metaDescription":"Siemens SENTRON 5SV3412-6 RCCB, 25 A rated, 100 mA trip, Type A, 2-pole, 10 kA SCCR, 230/400 V AC, DIN rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"25 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","I2t value permissible":"58 000 A²·s","Residual Current Type":"A","at 40 °C rated value":"25 A","at 45 °C rated value":"25 A","at 50 °C rated value":"25 A","at 55 °C rated value":"25 A","at 60 °C rated value":"25 A","at 65 °C rated value":"23.3 A","at 70 °C rated value":"17.6 A","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","Let-Through Current Permissible":"5 200 A","Tripping Fault Current Rated Value":"100 mA","Surge Current Resistance Rated Value":"1 kA","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"230/400 V","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"100 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"0.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48087f68ada23a812167cc92f76e12fe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=90190&mlfb=5SV3412-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3412-6/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for 5SV3412-6?","answer":"2-pole RCCB, 25 A rated current, 100 mA residual trip current, Type A, 10 kA SCCR at 230/400 V AC, 50 Hz, instantaneous tripping."},{"question":"What is the width and depth of 5SV3412-6?","answer":"Width is 36 mm (2 modular units), depth is 70 mm, height is 90 mm. It occupies 2 slots at 60 mm grid spacing."},{"question":"How do I get pricing and availability for 5SV3412-6?","answer":"Submit an RFQ for this order code. Current pricing and availability are confirmed at quote time through our independent distribution network."},{"question":"What compliance documentation is available for 5SV3412-6?","answer":"The part is designed to IEC 61008-1. It carries a silicon-free designation. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3412-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3412-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}