{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3416-8","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3416-8","canonicalUrl":"https://aoctrl.com/siemens/5SV3416-8","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3416-8","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON selective RCCB, 2-pole, 63 A, 100 mA Type A, 10 kA, DIN rail, IP20.","salesMarkdown":"The Siemens SENTRON 5SV3416-8 is a selective residual current circuit breaker (RCCB) — 2-pole, rated 63 A at 50/60 Hz, with a 100 mA Type A trip threshold. Selective (time-delayed) design means it coordinates with downstream RCDs: on a ground fault, the downstream device clears first, keeping this unit and upstream circuits live. Rated short-circuit withstand is 10 kA per IEC 61008-1, with an I²t let-through of 110,000 A²·s. Selective (S-type) time delay prevents nuisance tripping when a downstream RCD clears a fault first, so it belongs at the distribution board feeding sub-panels or final circuits. The 63 A rating holds at ambient up to 55 °C without derating; at 65 °C it derates to 56.96 A, and at 70 °C to 48.2 A. ## Panel integration The IP20 rating applies only after the distribution board is installed and conductors are connected — not a standalone outdoor rating. Silicon-free construction is confirmed, which matters for potting or conformal-coating processes in sensitive environments.","metaTitle":"Siemens SENTRON 5SV3416-8 RCCB, 63A, 100mA, Type A, 2-Pole","metaDescription":"Siemens SENTRON 5SV3416-8 selective RCCB, 63 A rated, 100 mA Type A, 2-pole, 10 kA SCCR. DIN rail mount, IP20. Current lifecycle stage. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3416-8","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, selective, In: 63 A, 100 mA, Un AC: 230 V","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"50/60 Hz","Product Designation":"RCCB","at AC / rated value":"63 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Selective","Residual Current Type":"A","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"63 A","at 45 °C / rated value":"63 A","at 50 °C / rated value":"63 A","at 55 °C / rated value":"63 A","at 60 °C / rated value":"63 A","at 65 °C / rated value":"56.96 A","at 70 °C / rated value":"48.2 A","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","acc. to EN 60898 / rated value":"0.8 kA","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","Tripping Fault Current / Rated Value":"100 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Current Resistance / Rated Value":"5 kA","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"No","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4e02c49688e748e3e27f3a39a45459d4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604180&mlfb=5SV3416-8"},"ai":{"faq":[{"question":"Where can I buy 5SV3416-8 and what is the lead time?","answer":"This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional alternative to 5SV3416-8?","answer":"The 5SL6550-7BB is a different class (MCB, not RCCB) and is not a direct functional substitute. For a selective Type A RCCB, stay within the SENTRON 5SV series."},{"question":"Will 5SV3416-8 drop into a panel specified around 5SL6550-7BB?","answer":"No — 5SL6550-7BB is a miniature circuit breaker (MCB), not an RCCB. The 5SV3416-8 is a 2-pole RCCB with a different function, wiring, and terminal arrangement. It will not drop in without rewiring."},{"question":"What compliance documentation does Siemens provide for 5SV3416-8?","answer":"The part carries IEC 61008-1 certification (0.8 kA rated breaking capacity per that standard) and EN 60898 compliance. Silicon-free construction is declared. RoHS/REACH declarations are typically available from Siemens upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3416-8","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3416-8 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}