{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3616-6KL","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3616-6KL","canonicalUrl":"https://aoctrl.com/siemens/5SV3616-6KL","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3616-6KL","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3616-6KL, RCCB, 63 A, 300 mA, Type A, 2-pole, instantaneous, DIN rail, 10 kA SCCR.","salesMarkdown":"The Siemens 5SV3616-6KL is a 2-pole RCCB from the SENTRON series, rated 63 A at 50 Hz with a 300 mA residual trip threshold. The 63 A rating holds continuously from 40 °C through 55 °C without derating; at 65 °C it drops to 56.96 A, and at 70 °C to 48.2 A. That thermal curve matters if this RCCB lives in a crowded enclosure or near a heat source — at 65 °C ambient you lose roughly 10 % of the headroom. The short-circuit current rating is 10 kA per IEC 61008-1, but the Icn according to EN 60898 is 0.8 kA. That split is common for RCCBs — the 10 kA figure is the conditional short-circuit rating with an upstream backup fuse or MCB; the 0.8 kA Icn is the rated breaking capacity without backup. In practice, coordinate this RCCB with a 10 kA MCB upstream to realize the full SCCR. The permissible I²t is 110 000 A²s, and the let-through current is rated at 7 100 kA — that last figure looks like a data artifact (likely 7.1 kA peak let-through), so treat it as the peak let-through under test conditions. Mounting position is any. Depth is 70 mm.","metaTitle":"Siemens 5SV3616-6KL SENTRON RCCB, 63 A, 300 mA, Type A, 2-po","metaDescription":"Siemens 5SV3616-6KL SENTRON RCCB, 63 A rated, 300 mA trip, Type A, 2-pole, 10 kA SCCR, instantaneous. DIN rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3616-6KL","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, In: 63 A, 300 mA, Un AC: 230 V, N left","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"N left","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"50 Hz","Product Designation":"RCCB","at AC / rated value":"63 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"63 A","at 45 °C / rated value":"63 A","at 50 °C / rated value":"63 A","at 55 °C / rated value":"63 A","at 60 °C / rated value":"63 A","at 65 °C / rated value":"56.96 A","at 70 °C / rated value":"48.2 A","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","acc. to EN 60898 / rated value":"0.8 kA","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Current Resistance / Rated Value":"1 kA","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"No","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Operating Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dad68b9571c5a593f46e55c9772911df.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=60164&mlfb=5SV3616-6KL"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3616-6KL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3616-6KL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}