{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3617-3","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3617-3","canonicalUrl":"https://aoctrl.com/siemens/5SV3617-3","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3617-3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 5SV3617-3, 2-pole, 80 A, 300 mA, Type F, short-time delayed, DIN rail mount, IP20.","salesMarkdown":"The Siemens SENTRON 5SV3617-3 is a 2-pole residual current circuit breaker (RCCB) rated for 80 A continuous load at 40 °C, tripping on a 300 mA residual current. The Type F designation means it handles sinusoidal AC faults plus composite and smooth DC fault currents up to 10 mA — common on variable-speed drives, washing machines, and other inverter-fed loads where standard AC types can blind. The short-time delayed switching function gives it a deliberate trip delay, so it coordinates downstream with instantaneous RCCBs and avoids nuisance trips from short-duration leakage spikes like those from connected electronics. Depth is 70 mm, height 90 mm. IP20 rating applies once installed with conductors connected; the enclosure provides the rest of the ingress protection. ## Thermal derating and short-circuit performance At 40 °C ambient it carries the full 80 A. Above that, the rated current drops: 77.87 A at 45 °C, 74.77 A at 50 °C, 70.26 A at 55 °C, 64.32 A at 60 °C, 56.96 A at 65 °C, and 48.2 A at 70 °C. The short-circuit current rating is 10 kA per IEC 61008-1, with an I²t let-through of 110 000 A²·s. The surge current resistance is rated at 3 kA, which covers most inrush from motor drives or switching power supplies without welding the contacts. ## What the approvals tell you Rated according to EN 60898 (0.8 kA rated value) and IEC 61008-1 (0.8 kA). Overvoltage category III. Silicon-free construction. The 50 Hz supply frequency is fixed — not suitable for 60 Hz systems without checking the manufacturer's frequency range. The minimum test voltage for the test circuit is 100 V.","metaTitle":"Siemens SENTRON 5SV3617-3 RCCB, 80 A, 300 mA, Type F, 2-Pole","metaDescription":"Siemens SENTRON 5SV3617-3 RCCB, 80 A rated, 300 mA residual current, Type F, 2-pole, short-time delayed. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","at AC / rated value":"80 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed","Residual Current Type":"F","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"80 A","at 45 °C / rated value":"77.87 A","at 50 °C / rated value":"74.77 A","at 55 °C / rated value":"70.26 A","at 60 °C / rated value":"64.32 A","at 65 °C / rated value":"56.96 A","at 70 °C / rated value":"48.2 A","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","acc. to EN 60898 / rated value":"0.8 kA","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Current Resistance / Rated Value":"3 kA","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"Yes","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Operating Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604193&mlfb=5SV3617-3","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3617-3/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the 5SV3617-3?","answer":"70 mm, which is standard for SENTRON DIN-rail RCCBs and matches the depth of most distribution board enclosures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3617-3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3617-3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}