{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3617-6KK01","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3617-6KK01","canonicalUrl":"https://aoctrl.com/siemens/5SV3617-6KK01","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3617-6KK01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3 RCCB, 5SV3617-6KK01, 2-pole, Type A, 80 A at 40 °C, 10 kA SCCR, 230/400 V AC, short-time delayed.","salesMarkdown":"The Siemens SENTRON 5SV3617-6KK01 is a 2-pole residual current circuit breaker (RCCB) in the 5SV3 short-time delayed design, rated 80 A at 40 °C and 230/400 V AC. The short-time delayed switching (often called 'selective' or 'S-type' in other brands) means it withstands brief surge currents — rated here at 3 kA — without tripping, so nuisance trips from lightning or capacitor-switching transients don't take a feeder offline while downstream MCBs clear a fault first. Snaps onto a DIN rail (REG profile), occupies 2 width units (36 mm), and accepts conductors from 0.75 mm² up to 35 mm² — solid or stranded. The 70 mm installation depth matches standard SENTRON modular-device spacing, so it sits flush in a distribution board alongside MCBs and surge arrestors. The IP20 rating applies only when the distribution board is installed with connected conductors — typical for enclosed panelboards, not for open racks. ## Thermal derating — the real-world current Above that, the continuous current drops: 77.87 A at 45 °C, 74.77 A at 50 °C, 70.26 A at 55 °C, 64.32 A at 60 °C, 56.96 A at 65 °C, and 48.19 A at 70 °C. The I²t value of 110 000 A²s is the let-through energy the device can withstand, relevant for coordination with upstream breakers. Overvoltage category III — suitable for fixed-installation distribution boards, not just downstream equipment. Finger and back-of-hand safe per the shock-protection classification. The part is assigned function F under DIN EN 61346-2 and DIN EN 81346-2, which is the standard functional designation for residual-current protective devices in industrial schematics. Silicon-free construction matters for applications where silicone outgassing can contaminate contacts or optics (e.g., automotive paint lines or clean-room panels).","metaTitle":"Siemens 5SV3617-6KK01 SENTRON RCCB, 80 A, 2-pole, Type A, 10","metaDescription":"Siemens 5SV3617-6KK01 SENTRON 5SV3 RCCB, 80 A rated at 40 °C, 2-pole, Type A, 10 kA SCCR, 230/400 V AC, short-time delayed. Current lifecycle, available to order. Quoted on request","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Solid":"0.75 ... 35 mm²","Width":"36 mm","Height":"90 mm","Stranded":"0.75 ... 35 mm²","at 40 Cel":"80 A","at 45 Cel":"77.87 A","at 50 Cel":"74.77 A","at 55 Cel":"70.26 A","at 60 Cel":"64.32 A","at 65 Cel":"56.96 A","at 70 Cel":"48.19 A","Rated Value":"50 Hz","Mounting type":"DIN rail (REG)","During Storage":"-40 ... +75 °C","Number of poles":"2","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +45 °C","Operating frequency":"50/60Hz","Product designation":"RCCB","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Short-time delayed","Number of width units":"2","Type of fault current":"A","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","I2t-value / permissible":"110 000 A²·s","circuit-breaker / Design":"5SV3","Short-circuit current rating":"10 kA","Current / at AC / rated value":"80 A","Product feature / silicon-free":"Yes","Position / of power supply cord":"top or bottom","Protection against electrical shock":"Finger and back-of-hand safe","Supply voltage / at AC / rated value":"230/400 V","Surge current resistance / rated value":"3 kA","Switching function / short-term delayed":"Yes","Tripping residual current / rated value":"300 mA","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Size of installation devices / acc. to DIN 43880":"1","Supply voltage / for testing equipment / minimum":"100 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4d1a0a2ac7b4c1613a28af67076c6723.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604194&mlfb=5SV3617-6KK01","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3617-6KK01/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV3617-6KK01 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here."},{"question":"Will 5SV3617-6KK01 drop into a panel specified around 5SY4116-7CV without rewiring?","answer":"No — the 5SY4116-7CV is a 1-pole MCB (16 A, B-curve) occupying 1 width unit. The 5SV3617-6KK01 is a 2-pole RCCB occupying 2 width units. The footprint, function, and wiring are completely different; you would need to re-engineer the feeder circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3617-6KK01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3617-6KK01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}