{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3617-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3617-7","canonicalUrl":"https://aoctrl.com/siemens/5SV3617-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3617-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON selective RCCB, 5SV3617-7, 2-pole, 80 A, 300 mA, Type F, 10 kA SCCR, DIN rail mount.","salesMarkdown":"The Type F designation means it detects sinusoidal AC residual currents plus pulsed DC and composite frequencies up to 1 kHz — covering variable-speed drives, inverters, and other non-sinusoidal loads that a standard Type A would miss. The selective design (time-delayed) lets it ride through short-duration earth faults so the downstream RCCB trips first, keeping upstream circuits live — essential for staged selectivity in a distribution board. The 80 A rating holds at 40 °C ambient; above that, derate per the published curve — 77.87 A at 45 °C, 74.77 A at 50 °C, stepping down to 48.2 A at 70 °C. The 300 mA trip threshold is typical for fire protection or equipment-level earth leakage where nuisance tripping from capacitive leakage (long cable runs, filter caps) must be avoided. IP20 applies once installed in a distribution board with conductors connected — not rated for open-panel or washdown environments. Silicon-free construction avoids outgassing concerns in sealed enclosures.","metaTitle":"Siemens SENTRON 5SV3617-7 RCCB, 80 A, 300 mA, Type F, Select","metaDescription":"Siemens SENTRON 5SV3617-7 selective RCCB, 80 A rated, 300 mA trip, Type F, 2-pole, 10 kA SCCR, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","at AC / rated value":"80 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Selective","Residual Current Type":"F","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"80 A","at 45 °C / rated value":"77.87 A","at 50 °C / rated value":"74.77 A","at 55 °C / rated value":"70.26 A","at 60 °C / rated value":"64.32 A","at 65 °C / rated value":"56.96 A","at 70 °C / rated value":"48.2 A","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 A","Tripping Fault Current / Rated Value":"300 mA","Surge Current Resistance / Rated Value":"5 kA","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"No","Value Range / Of The Operating Frequency":"50/60 Hz","value range / of the supply voltage / at AC":"230/400 V","Value Range / Of The Supply Voltage Frequency":"50 Hz","Supply Voltage / For Testing Equipment / Minimum":"100 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f019ed1b7501c392408cb735dbd307e0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604195&mlfb=5SV3617-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3617-7/alternatives.json"},"ai":{"faq":[{"question":"What is the 5SV3617-7 used for?","answer":"It is a selective Type F RCCB for 230/400 V AC, 50/60 Hz circuits, sized for 80 A loads with 300 mA earth leakage protection. The Type F characteristic covers variable-frequency drives and other loads that generate composite residual currents."},{"question":"How does the 5SV3617-7 differ from a standard Type A RCCB?","answer":"Type F detects sinusoidal AC, pulsed DC, and composite frequencies up to 1 kHz — where Type A only covers AC and pulsed DC. The selective (time-delayed) design adds intentional delay for coordination with downstream RCDs, unlike a standard instantaneous RCCB."},{"question":"Where can I buy the 5SV3617-7 and get pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3617-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3617-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}