{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3642-6KK01","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3642-6KK01","canonicalUrl":"https://aoctrl.com/siemens/5SV3642-6KK01","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3642-6KK01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3642-6KK01, 4-pole Type A RCCB, short-time delayed, rated 25 A, 300 mA residual, 400 V AC, 10 kA SCCR, DIN rail mount.","salesMarkdown":"The Siemens SENTRON 5SV3642-6KK01 is a 4-pole residual current operated circuit breaker (RCCB), Type A, short-time delayed, rated at 25 A and 300 mA residual sensitivity on a 400 V AC supply. Type A detection means it trips on sinusoidal AC residual currents and pulsating DC residual currents up to 300 mA — the standard for circuits with single-phase rectified loads like switched-mode power supplies or variable-speed drives. The short-time delayed characteristic (0.8 kA rated conditional short-circuit current per IEC 61008-1) prevents nuisance tripping from transient leakage or inrush in circuits with downstream surge arrestors or capacitive filters. At 72 mm wide (4 modular width units), it occupies four 18 mm slots on the rail. Depth is 70 mm, matching the standard 70 mm installation depth for SENTRON modular devices, so it sits flush in a common distribution board without protruding past the gland plate. IP20 rating applies once installed with conductors connected — the enclosure front is touch-safe, but the terminals are not protected against water ingress. This RCCB is specified in commercial and industrial distribution boards where earth-fault protection is required on a 4-wire (3-phase + neutral) system. The Type A characteristic makes it suitable for circuits feeding IT equipment, lighting with electronic ballasts, or small VFDs — loads that generate pulsating DC fault currents a standard Type AC RCCB might not detect. The short-time delay avoids nuisance tripping on circuits with surge protection devices or long cable runs with high capacitive leakage.","metaTitle":"Siemens 5SV3642-6KK01 SENTRON RCCB, 4-pole Type A, 25 A, 300","metaDescription":"Siemens SENTRON 5SV3642-6KK01 RCCB, 4-pole, Type A, short-time delayed, 25 A, 300 mA, 400 V AC. Active production. Sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"Yes","Value Range Of The Operating Frequency":"50/60 Hz","value range of the supply voltage at AC":"230/400 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"100 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"100 A","for rated value of the current at AC in hot operating state per pole":"0.8 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$55.88","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ed280646498d532ac59ddeccc41d4200.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604198&mlfb=5SV3642-6KK01","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3642-6KK01/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV3642-6KK01?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ against this order code; we source through independent distribution and provide a firm quote with current lead time."},{"question":"What compliance documentation does Siemens provide for this RCCB?","answer":"The 5SV3642-6KK01 is designed to IEC 61008-1 (RCCB standard) and carries a 10 kA SCCR rating. It is silicon-free, which is relevant for paint-shop or potting applications where silicone contamination must be avoided. Standard Siemens documentation includes the declaration of conformity to the applicable EU directives; specific RoHS/REACH declarations are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3642-6KK01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3642-6KK01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}