{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3654-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3654-6","canonicalUrl":"https://aoctrl.com/siemens/5SV3654-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3654-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 5SV3654-6, 4-pole Type A, In: 40 A, IΔn: 300 mA, Un AC: 500 V, instantaneous, DIN rail mount, IP20.","salesMarkdown":"The Siemens 5SV3654-6 is a SENTRON residual current circuit breaker (RCCB), 4-pole, Type A, rated 40 A with a 300 mA residual operating current and 500 V AC supply voltage. Depth is 70 mm, matching the installation depth of most SENTRON MCBs and RCCBs, so it aligns flush in a mixed row. Protection class is IP20 with the distribution board installed and conductors connected — standard for enclosed panel use. Supplementary devices (like auxiliary switches or shunt trips) can be installed on the side, and the unit is silicon-free, which matters for potting or conformal-coating compatibility in harsh-environment builds. The conditional short-circuit current with a 63 A series fuse (maximum permissible) is 0.8 kA — that is the rating when backed by an upstream MCB or fuse, which is the typical installation. Power dissipation is 1.8 W per pole at rated current in hot operating state — 7.2 W total for the 4-pole unit. Overvoltage category III (distribution level) confirms suitability for fixed-installation downstream of the utility meter.","metaTitle":"Siemens 5SV3654-6 SENTRON RCCB, 4-pole, 40A, 300mA, 500V","metaDescription":"Siemens 5SV3654-6 SENTRON RCCB, 4-pole, Type A, 40 A, 300 mA residual, 500 V AC. Active production. Sourced to order. Request quote for pricing and availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"72 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.8 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"500 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"100 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"1.8 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fc6d471a1349408b4cfcdef161388a5b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=675871&mlfb=5SV3654-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3654-6/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV3654-6?","answer":"Submit an RFQ for the 5SV3654-6; pricing and stock availability are confirmed at quote time through independent distribution channels."},{"question":"Will 5SV3654-6 drop into a panel that was specified around 5SL4363-7 without rewiring?","answer":"No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB), not an RCCB, so it serves a different protective function. The 5SV3654-6 is a 4-pole RCCB for earth leakage protection, while the 5SL4363-7 is a 3-pole MCB for overcurrent protection. They are not drop-in interchangeable."},{"question":"What is 5SV3654-6's listed depth on this component line?","answer":"The 5SV3654-6 has a depth of 70 mm, which matches the standard installation depth for SENTRON modular devices."},{"question":"What is 5SV3654-6's listed width on this component line?","answer":"The 5SV3654-6 has a width of 72 mm, corresponding to 4 modular width units at 60 mm grid spacing."},{"question":"What compliance documentation does Siemens provide for 5SV3654-6?","answer":"The 5SV3654-6 is designed according to IEC 61008-1 for RCCBs. It carries an IP20 protection class and is rated for overvoltage category III. The device is silicon-free, which aids compliance with certain coating and potting requirements. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3654-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3654-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}