{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV4311-0KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV4311-0KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV4311-0KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV4311-0KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 2-pole, Type AC, 16 A rated current, 30 mA rated residual current, supply voltage 24-125 VAC, 10 kA short-circuit current rating, instantaneous design.","salesMarkdown":"## RCCB for 24-125 VAC control circuits Rated 16 A continuous current with a 30 mA trip sensitivity, it covers standard personnel and property protection in circuits fed from 24 to 125 VAC supplies — common for control transformers, PLC power feeds, and auxiliary panel distribution where the line voltage is below the usual 230/400 V. Series fuse maximum permissible is 63 A — typical for a backup fuse ahead of the RCCB. IP20 with connected conductors in an enclosed distribution board. Silicon-free construction and the ability to install supplementary devices — such as auxiliary switches or shunt trips — are useful for panel builders who need to avoid silicone outgassing in contactor or relay environments. ## Integration into a 24 VDC panel environment For a 24 VAC control circuit — often fed from a 100 VA transformer — this RCCB provides ground-fault protection downstream of the transformer secondary. Operating temperature range -25 to +45 °C covers indoor panel environments; storage down to -40 °C allows winter transport without damage. Overvoltage category III (distribution level) confirms it is rated for the fixed-installation side of the supply.","metaTitle":"Siemens 5SV4311-0KK13 SENTRON RCCB 2P 16A 30mA Type AC","metaDescription":"Siemens 5SV4311-0KK13 SENTRON 2-pole RCCB, 16 A, 30 mA, Type AC, 24-125 VAC, 10 kA SCCR. Active production, sourced to order. RFQ for volume pricing and lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"Un AC: 24-125 V","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"24 -125 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"24 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"0.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/92120be4d54bc26ab3c66e96f4c87223.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=627796&mlfb=5SV4311-0KK13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV4311-0KK13/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of 5SV4311-0KK13?","answer":"2-pole RCCB, Type AC, 16 A rated current, 30 mA rated residual current, supply voltage 24-125 VAC, 10 kA short-circuit current rating, instantaneous trip, 50 Hz only, 2 MWU (36 mm wide), 70 mm depth."},{"question":"Will 5SV4311-0KK13 drop into a panel designed for 5SL4363-7?","answer":"No — the 5SL4363-7 is a 3-pole miniature circuit breaker (54 mm wide, 76 mm deep) vs the 5SV4311-0KK13 2-pole RCCB (36 mm wide, 70 mm deep). Different DIN-rail footprint, different function (overcurrent vs residual current). They are not drop-in interchangeable; a panel designed for the MCB would need re-wiring and a different slot allocation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV4311-0KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV4311-0KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}