{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV4416-0KL","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV4416-0KL","canonicalUrl":"https://aoctrl.com/siemens/5SV4416-0KL","factsUrl":"https://aoctrl.com/api/mcp/products/5SV4416-0KL","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV4 series RCCB, 2-pole, AC type, 63 A rated current, 100 mA residual tripping, 10 kA short-circuit current rating, 230/400 V AC, DIN rail mount, 70 mm depth.","salesMarkdown":"The Siemens 5SV4416-0KL is a 2-pole residual current circuit breaker (RCCB) from the SENTRON 5SV4 series, designed for AC fault currents. It carries a rated current of 63 A at ambient temperatures up to 60 °C without derating, and a 100 mA residual tripping threshold — a common choice for general-purpose shock protection in distribution boards where a higher trip level is acceptable to avoid nuisance tripping on leakage from filters or long cable runs. Rated 230/400 V AC, 10 kA SCCR. DIN rail mount, 2 width units (36 mm wide), 70 mm depth. ## Thermal performance and conductor sizing This RCCB holds its full 63 A rating from 40 °C through 60 °C ambient — no derating curve to track in most panel environments. At 65 °C it drops to 56.96 A, and at 70 °C to 48.19 A. For a panel running hot near the upper operating limit of -25 to +45 °C, the 63 A rating is fully available. Terminals accept 0.75 mm² to 35 mm² solid or stranded. I²t rating 110,000 A²s. ## Mounting and installation notes DIN rail (REG) mounting, any position allowed — no orientation restriction. The N-left product variation means the neutral pole is on the left side when viewed from the front, matching the standard SENTRON busbar layout for 2-pole RCCBs. IP20 when installed in distribution board with conductors connected. Finger and back-of-hand safe.","metaTitle":"Siemens 5SV4416-0KL SENTRON RCCB, 63 A, 100 mA, 2-pole, AC t","metaDescription":"Siemens 5SV4416-0KL SENTRON 2-pole RCCB, 63 A rated, 100 mA AC residual current, 10 kA SCCR. DIN rail mount, 70 mm deep. Current lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Solid":"0.75 ... 35 mm²","Width":"36 mm","Height":"90 mm","Stranded":"0.75 ... 35 mm²","at 40 Cel":"63 A","at 45 Cel":"63 A","at 50 Cel":"63 A","at 55 Cel":"63 A","at 60 Cel":"63 A","at 65 Cel":"56.96 A","at 70 Cel":"48.19 A","Rated Value":"50 Hz","Mounting type":"DIN rail (REG)","During Storage":"-40 ... +75 °C","Number of poles":"2","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Product variations":"N left","Ambient temperature":"-25 ... +45 °C","Product designation":"RCCB","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Number of width units":"2","Type of fault current":"AC","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","I2t-value / permissible":"110 000 A²·s","circuit-breaker / Design":"5SV4","Short-circuit current rating":"10 kA","Current / at AC / rated value":"63 A","Product feature / silicon-free":"Yes","Position / of power supply cord":"top or bottom","Protection against electrical shock":"Finger and back-of-hand safe","Supply voltage / at AC / rated value":"230/400 V","Switching function / short-term delayed":"No","Tripping residual current / rated value":"100 mA","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Size of installation devices / acc. to DIN 43880":"1","Supply voltage / for testing equipment / minimum":"100 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c780bdfe231a5e538173fedfa07d8eb4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=448553&mlfb=5SV4416-0KL","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV4416-0KL/alternatives.json"},"ai":{"faq":[{"question":"What conductor sizes does the 5SV4416-0KL accept?","answer":"Solid and stranded conductors from 0.75 mm² up to 35 mm². That covers typical distribution wiring from lighting circuits to main feeds."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV4416-0KL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV4416-0KL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}