{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV5316-0MB","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV5316-0MB","canonicalUrl":"https://aoctrl.com/siemens/5SV5316-0MB","factsUrl":"https://aoctrl.com/api/mcp/products/5SV5316-0MB","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 2-pole, Type AC, 63 A, 30 mA, 230 V AC, 60 Hz, DIN rail mount.","salesMarkdown":"The Siemens 5SV5316-0MB is a SENTRON residual current circuit breaker (RCCB), 2-pole, Type AC, rated 63 A with a 30 mA trip threshold for 230 V AC, 60 Hz circuits. The 63 A rating matches a typical main-switch or heavy-load subfeed; at 40 °C it holds the same 63 A, so no derating needed at normal panel ambient. The 6 kA short-circuit current rating is the breaking capacity under fault — adequate for most domestic and small commercial service entrances, but check your available fault current if you're feeding from a large transformer. It's Type AC, meaning it detects sinusoidal AC residual currents only; if your load includes rectifiers, VFDs, or switched-mode supplies, you'd want a Type A or F instead. ## Panel integration and compliance Supply can enter from top or bottom. The IP20 rating is standard for enclosed distribution boards — it's not a standalone outdoor device. Overvoltage category III suits fixed installation downstream of the utility meter.","metaTitle":"Siemens 5SV5316-0MB SENTRON RCCB, 2-pole, 63 A, 30 mA, Type","metaDescription":"Siemens SENTRON 5SV5316-0MB RCCB, 2-pole, 63 A, 30 mA, Type AC, 230 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV5316-0MB","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, Type AC, In: 63 A, 30 mA, Un AC: 230 V","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"60 Hz","Product Designation":"RCCB","at AC / rated value":"63 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"63 A","Short-Circuit Current Rating":"6 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","acc. to EN 60898 / rated value":"0.8 kA","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"60 Hz","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"No","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"2 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/156d1cc9583a4f09019b08c1a0b0077e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=906814&mlfb=5SV5316-0MB"},"ai":{"faq":[{"question":"Will 5SV5316-0MB drop into a panel specified around 5SY7206-7CC without rewiring?","answer":"They share the same 36 mm width (2 MW) and 70 mm installation depth, and both mount on DIN rail. The physical fit is the same — same footprint, same clip-on method. But the 5SY7206-7CC is a miniature circuit breaker (overcurrent + short-circuit), while the 5SV5316-0MB is an RCCB (residual-current only). You can swap the hardware into the same DIN slot, but the circuit function is different; the wiring and protection scheme must match the device type."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV5316-0MB","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV5316-0MB when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}