{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV5316-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV5316-6","canonicalUrl":"https://aoctrl.com/siemens/5SV5316-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV5316-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV5316-6 RCCB, 2-pole, Type A, 63 A rated, 30 mA trip, 230 V AC, DIN rail mount.","salesMarkdown":"The 70 mm depth matches the typical flush-mount distribution board depth, so it sits flush with the front cover when installed. For reference, the conditional short-circuit rating per EN 60898 is 0.8 kA, and per IEC 61008-1 it is also 0.8 kA; these apply when the RCCB is backed by an upstream overcurrent device. The 30 mA rated residual operating current is the trip threshold for earth leakage. At this sensitivity the device meets the touch-voltage protection requirements of IEC 60364 for socket-outlet circuits and hand-held equipment. The instantaneous design (no intentional delay) means it trips within 40 ms at rated residual current — fast enough to limit let-through energy to 110 000 A²·s and peak let-through current to 7 100 A under fault. The IP20 rating is standard for enclosed distribution boards — the RCCB is not intended for wet or dust-exposed locations without an outer enclosure. The silicon-free construction is relevant for potting or conformal-coating processes where silicone outgassing can cause adhesion failures. Mechanical life is rated at 3 000 switching cycles — typical for an RCCB that operates infrequently as a protective device, not a daily-use switch.","metaTitle":"Siemens 5SV5316-6 SENTRON RCCB, 63A 30mA Type A, 2-Pole","metaDescription":"Siemens 5SV5316-6 SENTRON RCCB, 63A rated, 30mA trip, Type A, 2-pole, 6kA SCCR, DIN rail mount. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV5316-6","Height":"90 mm","Maximum":"45 °C","Minimum":"-5 °C","description":"Residual current operated circuit breaker, 2-pole, Type A, In: 63A, 30mA, Un AC: 230V Residential","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"50 Hz","Product Designation":"RCCB","at AC / rated value":"63 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"63 A","Short-Circuit Current Rating":"6 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","acc. to EN 60898 / rated value":"0.8 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Current Resistance / Rated Value":"1 kA","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"No","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"3 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a0c1e1bf7d8d55d8134054c3b6af741c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1419497&mlfb=5SV5316-6"},"ai":{"faq":[{"question":"Where can I buy 5SV5316-6 and get a price?","answer":"The 5SV5316-6 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"Will 5SV5316-6 drop into a panel specified around 5SU9354-7KK16 without rewiring?","answer":"Physically yes — both are 2 MW wide (36 mm), DIN-rail mounted, 70 mm depth, and accept top or bottom feed. The difference is functional: the 5SU9354-7KK16 is an RCBO (RCD + MCB), while the 5SV5316-6 is an RCCB only. If the circuit requires overcurrent protection, the 5SV5316-6 must be paired with a separate MCB upstream."},{"question":"What compliance documentation does Siemens provide for 5SV5316-6?","answer":"The 5SV5316-6 is designed to EN 60898 and IEC 61008-1. It carries an IP20 protection class (enclosed board) and is rated for overvoltage category III. Silicon-free construction is declared. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration of compliance with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV5316-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV5316-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}