{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV5612-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV5612-6","canonicalUrl":"https://aoctrl.com/siemens/5SV5612-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV5612-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV5612-6 RCCB, 2-pole Type A instantaneous, 25 A at 40 °C, 300 mA residual trip, 6 kA SCCR, 230/400 V AC, DIN rail mount.","salesMarkdown":"## RCCB for panel builders — 25 A Type A, 300 mA trip The Siemens SENTRON 5SV5612-6 is a 2-pole residual current operated circuit breaker (RCCB) in Type A instantaneous design, rated 25 A at 40 °C with a 300 mA residual trip threshold. It operates on 230/400 V AC at 50 Hz and carries a 6 kA short-circuit current rating (SCCR) per IEC 61008-1. Depth is 70 mm; installation depth matches at 70 mm. Mounting position is any orientation. The instantaneous design (no short-time delay) means it trips within the standard RCCB response window, suitable for general distribution where selectivity with downstream RCBOs is managed by rating coordination rather than delay. The 6 kA SCCR (per IEC 61008-1) defines the maximum prospective fault current the device can interrupt without damage; verify that the upstream overcurrent protective device limits let-through to this value. The 1 kA surge current resistance and 0.5 kA rated value per IEC 61008-1 indicate the device withstands transient overvoltages common on residential mains without nuisance tripping.","metaTitle":"Siemens 5SV5612-6 SENTRON RCCB, 25A, 300mA, Type A, 2-Pole","metaDescription":"Siemens SENTRON 5SV5612-6 RCCB, 2-pole Type A, 25A rated, 300mA trip, 6kA SCCR, 230/400V AC. DIN rail mount, current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV5612-6","Height":"90 mm","Maximum":"45 °C","Minimum":"-5 °C","description":"Residual current operated circuit breaker, 2-pole, Type A, In: 25A, 300mA, Un AC: 230V Residential","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"25 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","I2t value permissible":"58 000 A²·s","Residual Current Type":"A","at 40 °C rated value":"25 A","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"6 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","Let-Through Current Permissible":"5 200 A","Tripping Fault Current Rated Value":"300 mA","Surge Current Resistance Rated Value":"1 kA","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"230/400 V","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"100 V","Mechanical Service Life (Operating Cycles) Typical":"3 000","Product Extension Installable Supplementary Devices":"No","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51bce3dc18fba9816145e7b7b5f4eeee.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1419501&mlfb=5SV5612-6"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV5612-6?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels; no real-time figures are published here."},{"question":"Will 5SV5612-6 drop into a panel specified around 5SY5232-6 without rewiring?","answer":"Both are 2-pole RCCBs on the same DIN-rail footprint (36 mm width, 2 MW), so the mechanical swap is straightforward. However, verify the residual current type and trip rating — the 5SV5612-6 is Type A, 300 mA, while the 5SY5232-6 may differ. If the panel design calls for a specific type or threshold, confirm the replacement matches the original specification before substituting."},{"question":"What compliance documentation does this brand provide for 5SV5612-6?","answer":"The SENTRON series is designed to IEC 61008-1. RoHS, REACH, and UL declarations are typically available from the manufacturer upon request; include these documentation requirements with your RFQ to ensure they accompany the shipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV5612-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV5612-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}