{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV5616-0","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV5616-0","canonicalUrl":"https://aoctrl.com/siemens/5SV5616-0","factsUrl":"https://aoctrl.com/api/mcp/products/5SV5616-0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV5616-0, 2-pole RCCB, Type AC, 63 A rated, 300 mA residual, 6 kA SCCR, 2 MW, DIN rail mount, IP20.","salesMarkdown":"The Siemens 5SV5616-0 is a 2-pole residual current operated circuit breaker (RCCB) from the SENTRON family, rated 63 A at 230 V AC with a 300 mA residual trip threshold, Type AC (sinusoidal AC fault currents only). It is an instantaneous-trip device (no intentional short-time delay), so it clears ground faults within one cycle — the right choice for general-purpose socket circuits and lighting where nuisance tripping from transient surges is not a concern. The 6 kA short-circuit current rating (SCCR) per EN 60898 and IEC 61008-1 means the device safely interrupts a fault up to that level without rupturing — adequate for most residential and light commercial distribution boards where the prospective fault current stays under 6 kA. Rated 63 A at 40 °C ambient, with a permissible I²t of 110 000 A²·s for through-fault energy let-through — useful for coordinating with downstream MCBs and ensuring the RCCB withstands the thermal stress of a bolted fault before the upstream device clears. Operating temperature range is -25 °C to +45 °C; storage range extends from -40 °C to +75 °C, so the device can be warehoused in unconditioned spaces but must be commissioned within the narrower operating band. Overvoltage category III — suitable for fixed-installation distribution boards where transient overvoltages from the utility side are expected. Silicon-free construction matters for automotive paint-shop or semiconductor-fab installations where silicone outgassing can contaminate surfaces; the 5SV5616-0 carries that designation.","metaTitle":"Siemens 5SV5616-0 SENTRON RCCB, 2-pole, 63 A, 300 mA, Type A","metaDescription":"Siemens 5SV5616-0 SENTRON 2-pole RCCB, 63 A, 300 mA residual, Type AC, 6 kA SCCR, IP20. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV5616-0","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, Type AC, In: 63 A, 300 mA, Un AC: 230 V","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"50 Hz","Product Designation":"RCCB","at AC / rated value":"63 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","I2t value / permissible":"110 000 A²·s","at 40 °C / rated value":"63 A","Short-Circuit Current Rating":"6 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"7 100 kA","according to EN 60898 / rated value":"0.8 kA","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","according to IEC 61008-1 / rated value":"0.8 kA","Switching Function / Short-Term Delayed":"No","Mechanical Service Life (Switching Cycles) / Typical":"2 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dcff0628b0eb2d7e5b939ca31c2a18bf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=467483&mlfb=5SV5616-0"},"ai":{"faq":[{"question":"What is the 5SV5616-0 used for?","answer":"It is a 2-pole residual current circuit breaker (RCCB) for 230 V AC circuits, rated 63 A with a 300 mA residual trip threshold, Type AC (sinusoidal AC faults). It provides ground-fault protection in residential and light commercial distribution boards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV5616-0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV5616-0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}