{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-6GV06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-6GV06","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-6GV06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-6GV06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV6 series, AFDD/MCB combination unit, 1P+N, 6 A, B-curve, 6 kA, 1 MW, DIN rail.","salesMarkdown":"It protects final circuits against overload, short-circuit (B-curve, 6 kA per EN 60898-1 and IEC 60947-2), and series/parallel arcing faults that standard breakers cannot detect. The 1P+N design switches the line and switches the neutral, making it suitable for single-phase 230 V AC, 50 Hz circuits in residential and commercial distribution boards. Rated at 6 A with a B-curve trip characteristic: the magnetic trip fires at 3–5× In (18–30 A), so it is a good match for resistive and general-purpose loads like lighting circuits, socket outlets, and small appliances — not for motor starting where a C or D curve would be needed to avoid nuisance trips on inrush. Breaking capacity of 6 kA per both EN 60898-1 and IEC 60947-2 means it can safely interrupt fault currents up to 6 kA at 230 V AC. For higher fault levels, step up to the 10 kA or 15 kA variants in the same family. The arc-fault detection function covers series arcs (minimum 2 A, maximum 6 A) and parallel arcs (minimum 50 A, maximum 500 A) — the range where smoldering faults in damaged cables or loose connections typically occur before they escalate to a hard short. Snaps onto a DIN rail (EN 60715) in any mounting position, takes one modular width (18 mm), and requires 70 mm installation depth behind the panel — the 68.5 mm body depth plus clearance for conductors.","metaTitle":"Siemens 5SV6016-6GV06 SENTRON AFDD/MCB, B6, 1P+N, 6kA","metaDescription":"Siemens 5SV6016-6GV06 SENTRON AFDD/MCB, 6A B-curve, 1P+N, 6kA breaking capacity per IEC 60898-1. Active production, sourced to order. DIN rail, 1 MW wide.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6016-6GV06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"5SV6 AFDD/MCB 6kA B06 1+N 1MW Big Pack 12 pcs","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","Position / Of Power Supply Cord":"any","according to EN 60898-1 / rated value":"6 000 A","according to IEC 60947-2 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"6 A","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50Hz","Ambient Temperature / With Relative Humidity 95%":"55 °C","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"6 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265720&mlfb=5SV6016-6GV06"},"ai":{"faq":[{"question":"Where can I buy 5SV6016-6GV06 and what is the price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"Will 5SV6016-6GV06 drop into a panel specified around 5SL3116-6MB without rewiring?","answer":"Not directly. The 5SV6016-6GV06 is an AFDD/MCB combination (1P+N, 2-pole) with a 68.5 mm depth, while the 5SL3116-6MB is a single-pole MCB (76 mm depth). The 5SV6 requires a neutral connection through the device, so the panel wiring must already bring the neutral to the breaker position. Both mount on DIN rail and share the same 18 mm width per pole, but the neutral switching changes the wiring scheme."},{"question":"What compliance documentation does Siemens provide for 5SV6016-6GV06?","answer":"The part is halogen-free and silicon-free. It carries ratings per EN 60898-1 and IEC 60947-2, which implies CE marking for the European market. Standard Siemens documentation includes a declaration of conformity and the product datasheet. Check the specific project requirements for UL or CSA — the listed ratings are to IEC/EN standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-6GV06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-6GV06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}