{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-6MC10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-6MC10","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-6MC10","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-6MC10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD-MCB combination, 5SV6016-6MC10, 2-pole 1P+N, Class B, 6 kA (EN 60898-1), 230 V AC, integrated metering, DIN rail mount, 18 mm width.","salesMarkdown":"## Arc-fault detection plus MCB in one module The Siemens 5SV6016-6MC10 is a SENTRON AFDD-MCB combination unit — an arc-fault detection device (AFDD) and a miniature circuit breaker (MCB) integrated into a single compact housing. It occupies just 18 mm width (1 modular unit) on a DIN rail, with a depth of 68.5 mm and height of 90 mm. The 2-pole design uses a 1P+N configuration, switching the line and monitoring the neutral for arc faults. Integrated metering sets this apart: the unit includes an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter. Measurement accuracy is 0.5 % for current and voltage, 1 % for active power, compliant with IEC 61557-12, IEC 62053-22, and IEC 62053-23. The front-panel display cycles through voltage, current, active/reactive/apparent power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, trip events, and warnings — giving a panel operator live circuit data without a separate meter. If your installation has a higher fault level (e.g., near a transformer substation), you would need an MCB with a higher breaking capacity, typically 10 kA or 25 kA. The 18 mm width (1 modular unit) is the standard DIN-rail pitch for a single-pole MCB. This unit packs a 2-pole AFDD+MCB plus metering into that same 18 mm.","metaTitle":"Siemens 5SV6016-6MC10 SENTRON AFDD-MCB, 6 kA, Class B, 2-Pol","metaDescription":"Siemens 5SV6016-6MC10 SENTRON AFDD-MCB combination unit. 6 kA breaking capacity (EN 60898-1), Class B trip, 230 V AC, 2-pole 1P+N. Integrated metering (ammeter, voltmeter, wattmete","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6016-6MC10","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","description":"AFDD-MCB-Combination Measuring, Communication AC 230V 6kA, 1+N pole, B, 10A Please consider Radio approval! List of countries: see Certificates","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Design Of Pole":"1P+N","Frequency Meter":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"AFDD-MCB combination","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Design Of The Product":"Compact unit","Protocol Is Supported":"wireless protocol","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"any","Tripping Characteristic Class":"B","Type Of Measured Value Detection":"seamless","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","according to EN 60898-1 rated value":"6 000 A","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","according to IEC 60947-2 rated value":"6 000 A","Guideline Via Radio-Controlled System":"2014/53/EU","Switching Function Short-Term Delayed":"No","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Measurable Line Frequency Full-Scale Value":"60 Hz","Measuring Category For Voltage Measurement":"CATIII according to IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50Hz","Ambient Temperature With Relative Humidity 95%":"55 °C","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1445917&mlfb=5SV6016-6MC10"},"ai":{"faq":[{"question":"What does the integrated metering measure on the 5SV6016-6MC10?","answer":"The unit measures voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, trip events, and warnings. Accuracy is 0.5 % for current and voltage, 1 % for active power."},{"question":"What is the physical size of the 5SV6016-6MC10?","answer":"Width is 18 mm (1 modular unit), height is 90 mm, depth is 68.5 mm. Installation depth allowance is 70 mm. It snaps onto standard DIN rail (REG) and can be mounted in any position."},{"question":"Is the 5SV6016-6MC10 suitable for railway applications?","answer":"Yes, it is rated for shock and vibration per IEC 61373, making it suitable for rolling stock and other transport applications. The wide temperature range (-40 °C to 75 °C) also supports unheated or outdoor enclosures."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-6MC10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-6MC10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}