{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-6MC13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-6MC13","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-6MC13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-6MC13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, AFDD-MCB combination, 5SV6016-6MC13, 1P+N, B-curve, 6 kA, 230 V AC, 18 mm (1 MW), 68.5 mm depth, integrated metering.","salesMarkdown":"## AFDD-MCB with integrated metering The Siemens 5SV6016-6MC13 is a SENTRON compact unit combining an arc-fault detection device (AFDD) with a miniature circuit breaker (MCB) and a full energy meter — ammeter, voltmeter, wattmeter, frequency meter, and reactive-power meter all built in. The MCB side trips with a B characteristic (3–5× In for magnetic release) and is rated at 6 kA breaking capacity per EN 60898-1 at 230 V. The arc-fault detection adds series arc recognition, so this single unit replaces what would otherwise be an AFDD + MCB + energy meter stack. ## What the metering tells you The display cycles through voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, and trip/warning counters. Measurement accuracy is 0.5 % for current and voltage, 1 % for active power, per IEC 61557-12, IEC 62053-22, and IEC 62053-23. That's utility-grade submetering precision — enough for tenant billing or energy allocation on a machine line. The unit also supports a wireless protocol for data export, so you can pull the metering values into a building management or SCADA system without a hardwired comms link.","metaTitle":"Siemens 5SV6016-6MC13 SENTRON AFDD-MCB, 1P+N, B-Char, 6 kA","metaDescription":"Siemens 5SV6016-6MC13 SENTRON AFDD-MCB combination unit. 1P+N, B-curve, 6 kA per EN 60898-1. Integrated metering (A, V, W, var, Hz). 18 mm wide, 68.5 mm deep. Current lifecycle sta","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6016-6MC13","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","description":"AFDD-MCB-Combination Measuring, Communication AC 230V 6kA, 1+N pole, B, 13A Please consider Radio approval! List of countries: see Certificates","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Design Of Pole":"1P+N","Frequency Meter":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"AFDD-MCB combination","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Design Of The Product":"Compact unit","Protocol Is Supported":"wireless protocol","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"any","Tripping Characteristic Class":"B","Type Of Measured Value Detection":"seamless","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","according to EN 60898-1 rated value":"6 000 A","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","according to IEC 60947-2 rated value":"6 000 A","Guideline Via Radio-Controlled System":"2014/53/EU","Switching Function Short-Term Delayed":"No","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Measurable Line Frequency Full-Scale Value":"60 Hz","Measuring Category For Voltage Measurement":"CATIII according to IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50Hz","Ambient Temperature With Relative Humidity 95%":"55 °C","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1445918&mlfb=5SV6016-6MC13"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-6MC13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-6MC13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}