{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-6MC32","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-6MC32","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-6MC32","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-6MC32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD-MCB combination, 1P+N, 230 V AC, 6 kA (EN 60898-1), B curve, 18 mm wide, compact unit.","salesMarkdown":"The Siemens SENTRON 5SV6016-6MC32 is an arc-fault detection device combined with a miniature circuit breaker (AFDD-MCB) in a single compact unit, 1P+N, rated 230 V AC with a B tripping curve and 6 kA breaking capacity per EN 60898-1. It integrates ammeter, voltmeter, wattmeter, frequency meter, and reactive power metering — all displayed on the front (IP40 front, IP20 rear with conductors connected). The measured variables include voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping events, and warnings. Snaps onto DIN rail (REG), occupies 1 modular width unit (18 mm), with a depth of 68.5 mm and installation depth of 70 mm. Mounting position is unrestricted. Shock and vibration per IEC 61373. Seamless measurement detection with accuracy: current and voltage 0.5 %, active power 1 %, per IEC 61557-12, IEC 62053-22, IEC 62053-23. Wireless protocol supported for data communication.","metaTitle":"SENTRON 5SV6016-6MC32 AFDD-MCB, 1P+N, 6 kA, B curve","metaDescription":"Siemens SENTRON 5SV6016-6MC32 AFDD-MCB combination, 1P+N, 6 kA per EN 60898-1, B curve, 230 V AC, 18 mm wide. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6016-6MC32","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","description":"AFDD-MCB-Combination Measuring, Communication AC 230V 6kA, 1+N pole, B, 32A Please consider Radio approval! List of countries: see Certificates","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Design Of Pole":"1P+N","Frequency Meter":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"AFDD-MCB combination","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Design Of The Product":"Compact unit","Protocol Is Supported":"wireless protocol","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"any","Tripping Characteristic Class":"B","Type Of Measured Value Detection":"seamless","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","according to EN 60898-1 rated value":"6 000 A","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","according to IEC 60947-2 rated value":"6 000 A","Guideline Via Radio-Controlled System":"2014/53/EU","Switching Function Short-Term Delayed":"No","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Measurable Line Frequency Full-Scale Value":"60 Hz","Measuring Category For Voltage Measurement":"CATIII according to IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50Hz","Ambient Temperature With Relative Humidity 95%":"55 °C","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"4.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1445922&mlfb=5SV6016-6MC32"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV6016-6MC32?","answer":"Submit an RFQ through the storefront; the part is sourced to order with availability and pricing confirmed at quote time."},{"question":"What is 5SV6016-6MC32's listed depth?","answer":"Depth is 68.5 mm; installation depth is 70 mm."},{"question":"What is 5SV6016-6MC32's listed width?","answer":"Width is 18 mm, which is 1 modular width unit on DIN rail."},{"question":"What compliance documentation does this brand provide for 5SV6016-6MC32?","answer":"The product is halogen-free and silicon-free, designed to IEC 61373 for shock, and its measurement accuracy follows IEC 61557-12, IEC 62053-22, and IEC 62053-23."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-6MC32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-6MC32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}