{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7GV06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7GV06","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7GV06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7GV06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD/MCB, 6 A, 230 V AC, 6 kA, 1P+N, 18 mm wide, DIN rail mount.","salesMarkdown":"The Siemens 5SV6016-7GV06 is a SENTRON arc-fault detection unit combined with a miniature circuit breaker (AFDD/MCB). It protects a 230 V AC final circuit against both overload/short-circuit and series or parallel arcing faults — the kind of low-energy, high-resistance arcs a standard MCB won't clear. The 1P+N configuration switches the line conductor only; the neutral is switched through but not protected. Installation depth is 70 mm, with the device body itself 68.5 mm deep. ## Arc-fault detection — what the thresholds mean The AFDD detects two arc modes. For series arcs (a loose connection or broken conductor in line with the load), the detection window runs from 1 A minimum up to 6 A maximum — right at the MCB's thermal rating, so it catches an arcing fault before the breaker's overcurrent trip would operate. For parallel arcs (line-to-neutral or line-to-ground), the detection range is 50 A minimum to 500 A maximum, covering the high-energy fault path. The unit does not include a short-time delay on the switching function; it trips instantaneously on arc detection. That 50 A minimum parallel-arc threshold is worth noting: it means the AFDD will not nuisance-trip on normal inrush from a motor or capacitive load that stays below that current level. The 500 A ceiling covers most branch-circuit arc faults without waiting for the MCB's magnetic trip at 6 kA. ## Panel fit and environmental tolerance Snaps onto DIN rail (REG) in any orientation.","metaTitle":"Siemens 5SV6016-7GV06 SENTRON AFDD/MCB, 6 A, 6 kA, 1P+N","metaDescription":"Siemens SENTRON 5SV6016-7GV06 arc-fault detection unit MCB. 6 A, 230 V AC, 6 kA breaking capacity (IEC/EN). 1P+N, 18 mm wide. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6016-7GV06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"5SV6 AFDD/MCB 6kA C06 1+N 1MW Big Pack 12 pcs","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Arc-fault detection unit MCB","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Number Of Poles / Note":"1P+N","Number Of Modular Width Units":"1","Position / Of Power Supply Cord":"any","acc. to IEC 60947-2 / rated value":"6 000 A","according to EN 60898-1 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"6 A","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"6 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"1 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265725&mlfb=5SV6016-7GV06"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV6016-7GV06?","answer":"6 kA rated according to both EN 60898-1 and IEC 60947-2."},{"question":"Where can I buy 5SV6016-7GV06 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or prices are published here."},{"question":"What does the AFDD detect — series arcs, parallel arcs, or both?","answer":"Both. Series arcs are detected from 1 A to 6 A; parallel arcs from 50 A to 500 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7GV06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7GV06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}