{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, AFDD+MCB combination, 1P+N, C-curve, 13 A, 6 kA, 230 V AC, 1 MW, compact unit.","salesMarkdown":"It's rated 13 A, C-curve, 230 V AC, with a 6 kA breaking capacity per both IEC 60947-2 and EN 60898-1. That 6 kA is the short-circuit capacity at the terminals; the real value here is the integrated arc-fault detection, which catches series arcs down to 2 A and parallel arcs up to 500 A. If your panel has a higher available fault current, you'll need to coordinate upstream or step to a higher-rated device. The arc-fault detection side is what separates this from a plain MCB. It detects low-energy series arcs (as low as 2 A) that a standard breaker won't trip on — those are the ones that start fires behind drywall or in junction boxes. The parallel arc detection (50 A to 500 A) covers the higher-energy fault between line and neutral or ground. This unit does both in one 18 mm slot, saving rail space over separate AFCI and MCB devices. The 1P+N configuration switches the phase and monitors the neutral, but does not switch the neutral — it's a solid neutral path through the device. That's standard for single-pole AFCI/GFCI breakers in North American practice, though this is a DIN-rail format for European and IEC-style panels. The neutral conductor is not disconnected when the breaker trips, which matters for maintaining circuit integrity downstream. Installation depth is 70 mm; the device body is 68.5 mm deep, so it sits flush with the rail edge. That covers unconditioned enclosures in most climates.","metaTitle":"Siemens SENTRON 5SV6016-7KK13 AFDD+MCB, 13A, C-curve, 6kA","metaDescription":"Siemens SENTRON 5SV6016-7KK13 arc-fault detection unit with MCB, 1P+N, 13A, C-curve, 6kA breaking capacity per IEC/EN. Active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6016-7KK13","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"AFDD-MCB-Combination 230V, 6kA, 1+N, C, 13A Compact (1MW)","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Arc-fault detection unit MCB","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"any","acc. to IEC 60947-2 / rated value":"6 000 A","according to EN 60898-1 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"13 A","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50Hz","Ambient Temperature / With Relative Humidity 95%":"55 °C","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"13 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1108727&mlfb=5SV6016-7KK13"},"ai":{"faq":[{"question":"What is the difference between the 5SV6016-7KK13 and a standard MCB like the 5SY3025-7KL?","answer":"The 5SV6016-7KK13 integrates arc-fault detection (AFDD) into the MCB body, catching series arcs from 2 A to 13 A and parallel arcs from 50 A to 500 A. A standard MCB like the 5SY3025-7KL provides only overcurrent and short-circuit protection — no arc-fault sensing. Both share the same 18 mm DIN-rail footprint, but the AFDD unit adds the series/parallel arc detection circuitry internally."},{"question":"Does the 5SV6016-7KK13 switch the neutral?","answer":"No. It is a 1P+N configuration that switches the phase conductor only; the neutral path is solid (not switched)."},{"question":"Where can I buy the 5SV6016-7KK13?","answer":"Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm delivery commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}