{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7KK32","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7KK32","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7KK32","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7KK32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD+MCB combination, 230 V AC, 32 A, C-curve, 1P+N, 6 kA, compact 1 MW unit.","salesMarkdown":"The Siemens SENTRON 5SV6016-7KK32 is a combined arc-fault detection device (AFDD) and miniature circuit breaker (MCB) in a single compact unit — 1 MW wide, 18 mm per DIN 43880. It carries a 32 A rated operational current at 230 V AC, 50 Hz, with a C tripping characteristic for moderate inrush loads like lighting banks or small motor circuits. Breaking capacity is 6 kA per both IEC 60947-2 and EN 60898-1, sufficient for most residential and light commercial final subcircuits. This is not a standalone MCB. The AFDD function monitors for series arcs (rated 2 A minimum to 32 A maximum) and parallel arcs (50 A minimum to 500 A maximum) — the ranges that cover loose terminals, crushed cables, and carbonised insulation in a 32 A final circuit. The 1P+N pole design switches the line and switches the neutral, so it fits single-phase subcircuits where neutral isolation is required. Snap-on DIN rail (REG) mounting per EN 60715, any orientation. The 18 mm width occupies one modular unit, and the 70 mm installation depth leaves clearance behind a standard 80 mm deep enclosure.","metaTitle":"Siemens SENTRON 5SV6016-7KK32 AFDD+MCB, 32A C-curve 1P+N","metaDescription":"Siemens SENTRON 5SV6016-7KK32 AFDD+MCB combination, 32A, C-curve, 1P+N, 6kA per IEC 60898-1. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"any","acc. to IEC 60947-2 / rated value":"6 000 A","according to EN 60898-1 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"32 A","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50Hz","Ambient Temperature / With Relative Humidity 95%":"55 °C","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"32 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1108731&mlfb=5SV6016-7KK32","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7KK32/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV6016-7KK32?","answer":"6 kA per both IEC 60947-2 and EN 60898-1 at 230 V AC."},{"question":"What is the difference between 5SV6016-7KK32 and a standard MCB like 5SL4106-7CC?","answer":"The 5SV6016-7KK32 integrates an arc-fault detection device (AFDD) with the MCB in one 18 mm unit; the 5SL4106-7CC is a standard MCB without AFDD. The 5SL4106-7CC is a 1-pole (1P) device rated 6 A, while the 5SV6016-7KK32 is 1P+N rated 32 A. Both share the same 18 mm width and DIN-rail mounting, but the AFDD function and neutral switching make the 5SV6016-7KK32 a direct replacement only where arc-fault protection is specified."},{"question":"Where can I buy 5SV6016-7KK32?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7KK32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7KK32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}