{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7KP13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7KP13","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7KP13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7KP13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV6016-7KP13 AFDD-MCB combination, 1P+N, C-curve, 13 A, 6 kA, 230 V AC, compact 1 MW unit, DIN rail mount.","salesMarkdown":"The 5SV6016-7KP13: The C-curve tripping characteristic means the magnetic trip operates at 5 to 10 times rated current (65 A to 130 A for this 13 A unit), suited for moderate inrush loads like lighting circuits or small motor starters. The 6 kA breaking capacity is the same under both EN 60898-1 and IEC 60947-2 — no derating needed when switching between residential and industrial standards. The arc-fault detection covers both series arcs (2 A to 13 A) and parallel arcs (50 A to 500 A), per the listed minimum and maximum values. The 1P+N design switches the neutral, which matters for single-phase final circuits where isolation of both poles is required. The 10 000 mechanical switching cycles is typical for this class — adequate for most panel duty, not for frequent switching applications. Mounts on DIN rail (REG) in any position — no orientation restrictions. The installation depth is 70 mm; the overall depth is 68.5 mm, so it sits flush with the rail. Halogen-free and silicon-free construction per the listed specs.","metaTitle":"Siemens 5SV6016-7KP13 SENTRON AFDD+MCB, 1P+N, C, 13A, 6kA","metaDescription":"Siemens SENTRON 5SV6016-7KP13 AFDD-MCB combination, 230V AC, 13A, C-curve, 6kA per EN 60898-1. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"any","according to EN 60898-1 / rated value":"6 000 A","according to IEC 60947-2 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"13 A","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50Hz","Ambient Temperature / With Relative Humidity 95%":"55 °C","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"13 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1268780&mlfb=5SV6016-7KP13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7KP13/alternatives.json"},"ai":{"faq":[{"question":"What is 5SV6016-7KP13's listed depth?","answer":"The overall depth is 68.5 mm; the installation depth on DIN rail is 70 mm."},{"question":"What is 5SV6016-7KP13's listed width?","answer":"The width is 18 mm, which is 1 modular width unit on a DIN rail."},{"question":"Will 5SV6016-7KP13 drop into a panel specified around 5SY3025-7KL without rewiring?","answer":"Both are 1-module-wide (18 mm) DIN-rail devices with the same installation depth (70 mm), so the footprint is identical. However, the 5SV6016-7KP13 is an AFDD-MCB combination with arc-fault detection, while the 5SY3025-7KL is a standard MCB without arc-fault functionality. The wiring connections differ — the AFDD requires a neutral connection for the arc-fault electronics. Verify the panel wiring before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7KP13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7KP13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}