{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7MC10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7MC10","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7MC10","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7MC10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD-MCB combo, 2-pole 1P+N, C-curve, 33 A full-scale, 6 kA IEC 60947-2, integrated metering, DIN rail.","salesMarkdown":"It's a 2-pole (1P+N) design with a C-curve tripping characteristic, rated for 230 V AC and a full-scale current of 33 A. The integrated metering suite — ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter — gives you live power-quality data without adding a separate panel meter. The AFDD function detects series and parallel arc faults per IEC 62606, so this unit covers both overcurrent protection and arc-fault protection in a single DIN-rail module. The 33 A full-scale is the maximum continuous current the metering electronics are calibrated for; the MCB's thermal trip element is sized for the same 33 A nominal. If your load draws more than 33 A steady-state, step up to the next frame size. The 6 kA rated short-circuit capacity (IEC 60947-2) is adequate for most sub-distribution boards fed from a transformer with typical impedance. Environmental range is wide: -40 °C to +75 °C operating/storage, pollution degree 2, overvoltage category III. Depth is 68.5 mm, installation depth 70 mm — verify enclosure depth clearance, especially in shallow pull-boxes. Front face is IP40; rear side is IP20. With conductors and protective device connected, the overall assembly meets IP20.","metaTitle":"Siemens 5SV6016-7MC10 SENTRON AFDD-MCB, C-curve 2-pole, 33 A","metaDescription":"Siemens 5SV6016-7MC10 SENTRON AFDD-MCB combo, 2-pole 1P+N, C-curve, 33 A full-scale, 6 kA IEC 60947-2. Integrated ammeter/voltmeter/wattmeter/frequency meter. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Initial Value":"0.04 A","Design Of Pole":"1P+N","Frequency Meter":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Full-Scale Value":"33 A","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"AFDD-MCB combo","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Design Of The Product":"Compact unit","Protocol / Is Supported":"wireless protocol","For Measured Variable Output":"+/- 1%","For Measured Variable Voltage":"+/- 0.5%","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"any","Type Of Measured Value Detection":"seamless","acc. to IEC 60947-2 / rated value":"6 000 A","For Measured Variable Active Power":"+/- 1 %","For Measured Variable Output Factor":"+/- 0,5 %","For Measured Variable Reactive Power":"+/- 1%","Status Display / Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","according to EN 60898-1 / rated value":"6 000 A","Guideline / Via Radio-Controlled System":"2014/53/EU","Switching Function / Short-Term Delayed":"No","Measurable Line Frequency / Initial Value":"45 Hz","operational current / at AC / rated value":"10 A","Type Of Voltage / Of The Operating Voltage":"AC","Reference Condition / For Metering Accuracy":"according to IEC61557-12, IEC62053-22 and IEC62053-23","Measurable Line Frequency / Full-Scale Value":"60 Hz","Measuring Category / For Voltage Measurement":"CATIII according to IEC 61010-2-030","Frequency / With Radio Transmission / Maximum":"2 483.5 MHz","Frequency / With Radio Transmission / Minimum":"2 400 MHz","Measuring Procedure / For Current Measurement":"TRMS","Measuring Procedure / For Voltage Measurement":"TRMS","Value Range / Of The Supply Voltage Frequency":"50Hz","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","Ambient Temperature / With Relative Humidity 95%":"55 °C","Apparent Power Consumption / Of The Power Supply":"0.4 V·A","size of installation devices / acc. to DIN 43880":"1","reference current (Iref) / 1 / at AC / rated value":"10 A","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"10 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1445925&mlfb=5SV6016-7MC10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7MC10/alternatives.json"},"ai":{"faq":[{"question":"What is 5SV6016-7MC10's listed depth?","answer":"The unit depth is 68.5 mm, with an installation depth of 70 mm."},{"question":"What is 5SV6016-7MC10's width?","answer":"Width is 18 mm, which is 1 modular width unit on standard DIN rail."},{"question":"Will 5SV6016-7MC10 drop into a panel specified around 5SL6120-7 without rewiring?","answer":"No — the 5SV6016-7MC10 is an AFDD-MCB combo with integrated metering, while the 5SL6120-7 is a standard MCB without arc-fault detection or metering. The wiring and functional requirements differ; a direct swap without circuit redesign is not recommended."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7MC10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7MC10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}