{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7MC13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7MC13","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7MC13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7MC13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV6016-7MC13, 2-pole C-curve miniature circuit breaker, 33 A full-scale, 230 V AC, with integrated ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter, 18 mm wide, DIN-rail mount.","salesMarkdown":"## What this SENTRON unit does It integrates an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter — so it measures voltage, current, active power, apparent power, frequency, and reactive power in one DIN-rail package. Accuracy on current and voltage is 0.5 %; active and apparent power accuracy is 1 %, per IEC 61557-12, IEC 62053-22, and IEC 62053-23. That means you get revenue-grade metering without a separate meter module.","metaTitle":"Siemens SENTRON 5SV6016-7MC13 2-pole C-curve MCB, 33 A, 230","metaDescription":"Siemens SENTRON 5SV6016-7MC13 2-pole MCB, C-curve, 33 A full-scale, 230 V AC. Built-in ammeter, voltmeter, wattmeter, frequency & reactive power meter. IP20 rear, IP40 front. Halog","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Initial Value":"0.04 A","Design Of Pole":"1P+N","Frequency Meter":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Full-Scale Value":"33 A","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Design Of The Product":"Compact unit","Protocol / Is Supported":"wireless protocol","Standards / For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"any","Type Of Measured Value Detection":"seamless","For Measured Variable Active Power":"1 %","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","Status Display / Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","according to EN 60898-1 / rated value":"6 000 A","according to IEC 60947-2 / rated value":"6 000 A","For Measured Variable Electrical Energy":"1 %","Guideline / Via Radio-Controlled System":"2014/53/EU","Switching Function / Short-Term Delayed":"No","Measurable Line Frequency / Initial Value":"45 Hz","operational current / at AC / rated value":"13 A","Type Of Voltage / Of The Operating Voltage":"AC","Measurable Line Frequency / Full-Scale Value":"60 Hz","Measuring Category / For Voltage Measurement":"CATIII according to IEC 61010-2-030","Frequency / With Radio Transmission / Maximum":"2 483.5 MHz","Frequency / With Radio Transmission / Minimum":"2 400 MHz","Measuring Procedure / For Current Measurement":"TRMS","Measuring Procedure / For Voltage Measurement":"TRMS","Value Range / Of The Supply Voltage Frequency":"50Hz","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","Ambient Temperature / With Relative Humidity 95%":"55 °C","Apparent Power Consumption / Of The Power Supply":"0.4 VA","reference current (Iref) / 1 / at AC / rated value":"13 A","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"13 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1445926&mlfb=5SV6016-7MC13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7MC13/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV6016-7MC13?","answer":"Pricing and availability are confirmed at quote time against an RFQ through independent distribution — the part is sourced to order."},{"question":"What is 5SV6016-7MC13's listed depth on this component line?","answer":"The depth is 68.5 mm; installation depth is 70 mm."},{"question":"What is 5SV6016-7MC13's listed width on this component line?","answer":"The width is 18 mm — one modular width unit on a DIN rail."},{"question":"What compliance documentation does this brand provide for 5SV6016-7MC13?","answer":"The unit is designed to IEC 61557-12, IEC 62053-22, and IEC 62053-23 for metering accuracy. It is halogen-free and silicon-free. Specific RoHS/REACH/UL declarations should be requested at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7MC13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7MC13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}