{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6016-7MC32","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6016-7MC32","canonicalUrl":"https://aoctrl.com/siemens/5SV6016-7MC32","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7MC32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, C-curve, 6 kA per EN 60898-1, 230 V AC, 18 mm modular width, DIN rail mount, IP20 rear / IP40 front, -40 to 75 °C.","salesMarkdown":"## What this SENTRON RCBO does on the rail The Siemens 5SV6016-7MC32 is a 1P+N RCBO from the SENTRON family — a compact unit that combines overcurrent protection and residual current detection in one 18 mm-wide module. The rear side carries IP20 protection; the front face is IP40, so it's fine inside a standard panel but not meant for washdown. What sets this one apart from a plain MCB is the built-in metering. It measures voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, and trip events — and it displays them on the front. Accuracy on voltage and current is 0.5 %; on active and apparent power it's 1 %. That's enough to track load trends on a pump or conveyor leg without adding a separate power meter.","metaTitle":"Siemens SENTRON 5SV6016-7MC32 RCBO, C-Curve 6kA, 1P+N, 18mm","metaDescription":"Siemens SENTRON 5SV6016-7MC32 RCBO, 1P+N, C-curve, 6kA breaking capacity per EN 60898-1. 18mm wide, DIN rail mount. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","Height":"90 mm","Ammeter":"Yes","Maximum":"75 °C","Minimum":"-40 °C","Rear Side":"IP20","Voltmeter":"Yes","Wattmeter":"Yes","For Shocks":"IEC 61373","Halogen-Free":"Yes","On The Front":"IP40","Silicon-Free":"Yes","Design Of Pole":"1P+N","Frequency Meter":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Reactive Power Meter":"Yes","Design Of The Product":"Compact unit","Protocol Is Supported":"wireless protocol","Standards For Error Limits":"based on IEC61557-12, IEC62053-22, IEC62053-23","For Measured Variable Current":"0.5 %","For Measured Variable Voltage":"0.5 %","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"any","Tripping Characteristic Class":"C","Type Of Measured Value Detection":"seamless","For Measured Variable Active Power":"1 %","Status Display Of The Measured Data":"voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping, warnings","according to EN 60898-1 rated value":"6 000 A","For Measured Variable Apparent Power":"1 %","For Measured Variable Reactive Power":"1 %","according to IEC 60947-2 rated value":"6 000 A","Guideline Via Radio-Controlled System":"2014/53/EU","Switching Function Short-Term Delayed":"No","For Measured Variable Electrical Energy":"1 %","Measurable Line Frequency Initial Value":"45 Hz","Type Of Voltage Of The Operating Voltage":"AC","Frequency With Radio Transmission Maximum":"2 483.5 MHz","Frequency With Radio Transmission Minimum":"2 400 MHz","Measurable Line Frequency Full-Scale Value":"60 Hz","Measuring Category For Voltage Measurement":"CATIII according to IEC 61010-2-030","Measuring Procedure For Current Measurement":"TRMS","Measuring Procedure For Voltage Measurement":"TRMS","Value Range Of The Supply Voltage Frequency":"50Hz","Ambient Temperature With Relative Humidity 95%":"55 °C","Apparent Power Consumption Of The Power Supply":"0.4 VA","For Environmental Sinusoidal Oscillation Check":"IEC 60068-2-6","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"4.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e2939b7046519e3be2f5a5be6711c6b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1445930&mlfb=5SV6016-7MC32","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV6016-7MC32/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV6016-7MC32 and how do I get a price?","answer":"We source this part through independent distribution and quote it to order against an RFQ. Send the order code to your sourcing desk for a current price and availability confirmation."},{"question":"What is 5SV6016-7MC32's listed depth?","answer":"The depth is 68.5 mm, with an installation depth of 70 mm when conductors are connected."},{"question":"What is 5SV6016-7MC32's listed width?","answer":"Width is 18 mm, which is one modular unit on a DIN rail."},{"question":"What compliance standards does this RCBO meet?","answer":"It's built to IEC 61557-12, IEC 62053-22, and IEC 62053-23 for metering accuracy, and EN 60898-1 for breaking capacity (6 kA). Shock and vibration are rated per IEC 61373. Overvoltage category is III, pollution degree 2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6016-7MC32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6016-7MC32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}