{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6316-7FM16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6316-7FM16","canonicalUrl":"https://aoctrl.com/siemens/5SV6316-7FM16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6316-7FM16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD+RCBO, 1P+N, 230 V AC, 16 A, C-curve, 30 mA Type A, 6 kA, 1 MW wide, DIN rail.","salesMarkdown":"## Combined arc-fault and residual-current protection in one 18 mm package It integrates two protective functions that normally occupy separate modules: a 16 A, C-curve MCB for overcurrent and short-circuit, plus a 30 mA Type A RCD for earth leakage, all topped with an arc-fault detector that trips on series and parallel arcs. The unit snaps onto DIN rail (REG) and is rated 6 kA breaking capacity per both EN 60898-1 and IEC 60947-2, so it covers residential and light commercial panelboards where those standards apply. The 16 A rated operational current with C-curve tripping means this unit handles moderate inrush loads — think lighting banks, small motor circuits, or general socket outlets — without nuisance trips on startup. The 30 mA residual-current trip is Type A, so it detects pulsating DC fault currents from rectified loads like switched-mode power supplies or VFDs, not just pure sine-wave AC leakage. That matters in modern panels where electronics are common. The arc-fault detection covers both series arcs (2 A to 16 A minimum/maximum) and parallel arcs (50 A to 500 A), which is the full range a loose connection or damaged cable can produce. ## Mounting and environment — DIN rail, any position, wide temperature range Installation depth is 70 mm; the unit itself is 68.5 mm deep and 90 mm tall. The IP20 rating is typical for enclosed panel gear — the protection is complete once the panel door is closed and conductors are connected.","metaTitle":"Siemens SENTRON 5SV6316-7FM16 AFDD+RCBO, 16A C 30mA 6kA","metaDescription":"Siemens SENTRON 5SV6316-7FM16 combined AFDD and RCBO, 1P+N, 16 A, C-curve, 30 mA Type A, 6 kA per EN 60898-1. Current lifecycle stage, available to order. DIN rail mount, 18 mm wid","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6316-7FM16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"AFDD-RCBOele 230V, 6kA, 1P+N, C, 16A Compact (1MW), red i2","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact device, i1= 1.0xIn; i2= 1.2xIn","Residual Current Type":"A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"any","Tripping Fault Current / Rated Value":"30 mA","according to EN 60898-1 / rated value":"6 000 A","according to IEC 60947-2 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"16 A","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50Hz","Ambient Temperature / With Relative Humidity 95%":"55 °C","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"16 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3804ae6562ab35b234b77d05a03434cd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1399061&mlfb=5SV6316-7FM16"},"ai":{"faq":[{"question":"Will the 5SV6316-7FM16 drop into a panel specified for a standard MCB like the 5SL6120-7?","answer":"The 5SV6316-7FM16 shares the same 18 mm width, 90 mm height, and DIN rail mounting as the 5SL6120-7 miniature circuit breaker, so it fits the same panel footprint. However, the 5SV6316-7FM16 is a combined AFDD+RCBO requiring both line and neutral connections (1P+N), whereas the 5SL6120-7 is a single-pole MCB. Verify neutral bar access and wiring space before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6316-7FM16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6316-7FM16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}