{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6316-7KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6316-7KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV6316-7KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6316-7KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD-RCBO, 230 V AC, 6 A, C characteristic, 30 mA residual current, 1P+N, 6 kA, 1 MW, compact.","salesMarkdown":"## Arc-fault and residual-current protection in one 18 mm slot The Siemens SENTRON 5SV6316-7KK06 is a combined arc-fault detection device and residual-current circuit breaker (AFDD-RCBO) that packs overcurrent, earth leakage, and series/parallel arc-fault protection into a single 18 mm-wide module. The 6 A rated current with C-curve magnetic release suits circuits with moderate inrush — think lighting banks, socket outlets, or small appliance groups. The 30 mA residual-current element (type A) detects pulsating DC fault currents common in electronics, so it covers modern loads with rectified front ends. Arc-fault detection covers both series arcs (2 A to 6 A) and parallel arcs (50 A to 500 A), addressing the two main failure modes that standard MCBs and RCCBs cannot see. The 1-pole + N design switches the phase and monitors the neutral; the neutral pole is switched, not just sensed, which matters for full isolation. Mounting position is unrestricted — the arc-fault detection electronics are orientation-independent.","metaTitle":"Siemens 5SV6316-7KK06 SENTRON AFDD-RCBO, 6A C-curve, 30mA, 1","metaDescription":"Siemens SENTRON 5SV6316-7KK06 AFDD-RCBO, 6A C-curve, 30mA residual current, 6kA breaking capacity. 18mm wide, DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6316-7KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"AFDD-RCBOele 230V, 6kA, 1P+N, C, 6A Compact (1MW)","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"AFDD-RCBO","at AC / rated value":"230 V","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Residual Current Type":"A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"any","acc. to IEC 60947-2 / rated value":"6 000 A","Tripping Fault Current / Rated Value":"30 mA","according to EN 60898-1 / rated value":"6 000 A","Switching Function / Short-Term Delayed":"No","operational current / at AC / rated value":"6 A","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50Hz","Ambient Temperature / With Relative Humidity 95%":"55 °C","size of installation devices / acc. to DIN 43880":"1","Mechanical Service Life (Switching Cycles) / Typical":"10 000","In The Event Of Electrical Arcs In Series With The Load / Maximum":"6 A","In The Event Of Electrical Arcs In Series With The Load / Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load / Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load / Minimum":"50 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3ab374404a54b8b791b90b0c98e87d57.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1108733&mlfb=5SV6316-7KK06"},"ai":{"faq":[{"question":"Where can I buy 5SV6316-7KK06 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."},{"question":"What is the depth of 5SV6316-7KK06?","answer":"The device depth is 68.5 mm, with an installation depth of 70 mm. The 18 mm width occupies one modular unit on DIN rail."},{"question":"Will 5SV6316-7KK06 drop into a panel specified around 5SY3025-7KL?","answer":"The 5SV6316-7KK06 is a combined AFDD-RCBO, whereas the 5SY3025-7KL is a standard MCB without arc-fault or residual-current functionality. They share the same 18 mm DIN-rail footprint and 1 MW form factor, so the physical fit is the same, but the 5SV6316-7KK06 adds arc-fault detection and RCD protection that the MCB does not provide. Rewiring the neutral connection is required because the AFDD-RCBO switches the neutral pole."},{"question":"What compliance documentation does Siemens provide for 5SV6316-7KK06?","answer":"The device is halogen-free and silicon-free. Breaking capacity is certified to both IEC 60898-1 and IEC 60947-2 at 6 kA. Standard Siemens declarations of conformity (CE, UKCA) and RoHS/REACH statements are available through the product documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6316-7KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6316-7KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}