{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6316-7KK10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6316-7KK10","canonicalUrl":"https://aoctrl.com/siemens/5SV6316-7KK10","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6316-7KK10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD-RCBO combination, 230V AC, 10A, C-curve, 6kA, 1P+N, compact 1MW unit.","salesMarkdown":"It occupies 1 modular width (18 mm) on a DIN rail, installs in any mounting position, and carries a 6 kA breaking capacity per EN 60898-1 and IEC 60947-2 — enough for residential and light commercial final circuits. The unit is 1P+N (2 poles), switches the line and neutral, and is halogen-free and silicon-free — that's another SKU that won't off-gas in a fire or contaminate sensitive electronics nearby. The AFDD (arc-fault detection) function monitors for series and parallel arcs — a requirement in some national wiring regulations for circuits in sleeping rooms, care homes, or wooden buildings. The RCBO (residual-current) side adds 30 mA (typical) earth leakage protection, though the exact sensitivity isn't listed here — verify the nameplate for the residual rating. That covers unheated storage areas, outdoor enclosures, or hot attic spaces. Because it's a standard DIN-rail component (18 mm wide, 68.5 mm deep, 90 mm tall), it drops into any panel already laid out for SENTRON or similar modular devices. The supply cord can enter from any direction — top, bottom, or side — which helps when the panel layout is tight. Supplementary devices (like shunt trips or auxiliary contacts) can be added on the side, per the product extension feature. IP20 with connected protective devices and conductors — that's the usual for a panel-mounted breaker. No washdown rating; keep it inside a closed enclosure.","metaTitle":"Siemens 5SV6316-7KK10 SENTRON AFDD-RCBO, 10A C-curve, 6kA, 1","metaDescription":"Siemens 5SV6316-7KK10 SENTRON AFDD-RCBO combination, 230V AC, 10A, C-curve, 6kA breaking capacity, 1P+N, 18mm wide, active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","title":"5SV6316-7KK10","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"AFDD-RCBOele 230V, 6kA, 1P+N, C, 10A Compact (1MW)","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"AFDD-RCBO combination","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"any","Tripping Characteristic Class":"C","according to EN 60898-1 rated value":"6 000 A","according to IEC 60947-2 rated value":"6 000 A","Switching Function Short-Term Delayed":"No","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50Hz","Ambient Temperature With Relative Humidity 95%":"55 °C","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.66 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/71ebb5f25875a354f216f626a1184424.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1108734&mlfb=5SV6316-7KK10"},"ai":{"faq":[{"question":"Where can I buy 5SV6316-7KK10 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest lead time."},{"question":"Will 5SV6316-7KK10 drop into a panel specified around 5SL6120-7 without rewiring?","answer":"Not directly. The 5SL6120-7 is a 1-pole miniature circuit breaker (MCB) with a different function — it lacks the AFDD and RCBO functions. The 5SV6316-7KK10 is a 1P+N AFDD-RCBO combination, so it needs a neutral connection and occupies the same 18 mm width but serves a different protection role. You'd need to rewire the circuit to use it as a replacement."},{"question":"What compliance documentation does Siemens provide for 5SV6316-7KK10?","answer":"The part carries CE marking per the Low Voltage Directive and is designed to EN 60898-1 and IEC 60947-2. It is halogen-free and silicon-free, which supports RoHS compliance. For specific UL, CSA, or REACH declarations, request the manufacturer's declaration with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6316-7KK10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6316-7KK10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}