{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV6316-7KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV6316-7KK16","canonicalUrl":"https://aoctrl.com/siemens/5SV6316-7KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV6316-7KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON AFDD-RCBO, 230 V AC, 1P+N, 2-pole, C characteristic, 16 A rated current, 30 mA residual current, Type A, 6 kA breaking capacity, compact 1 MW unit, DIN rail mounting.","salesMarkdown":"The Siemens SENTRON 5SV6316-7KK16 is a combined arc-fault detection device (AFDD) and residual-current circuit breaker (RCBO) in a single 1-module-wide (18 mm) compact unit. It integrates overcurrent protection (C characteristic, 16 A rated current), residual-current protection (Type A, 30 mA trip threshold), and arc-fault detection per IEC/EN 62606 into one DIN-rail device. That means one part handles three failure modes — overload, short-circuit, earth leakage, and series/parallel arcing — in a single panel slot. Rated at 230 V AC, 16 A with a C trip curve, it's sized for general-purpose lighting and socket-outlet circuits where moderate inrush (motors, transformers) is expected. The 30 mA Type A residual-current element catches sinusoidal AC faults and pulsed DC fault currents up to 6 mA smooth DC — covers most modern electronics and variable-speed drive leakage without nuisance tripping. The arc-fault detection is rated for series arcs down to 2 A and parallel arcs from 50 A to 500 A, so it will clear a loose neutral screw or a frayed cable before the insulation catches fire. Snap-on DIN rail (REG) mounting, 18 mm width (1 MW), 68.5 mm depth, 70 mm installation depth. Terminal protection is IP20 with conductors and protective device fitted — standard for enclosed distribution boards.","metaTitle":"Siemens SENTRON 5SV6316-7KK16 AFDD-RCBO, 1P+N, C, 16 A, 30 m","metaDescription":"Siemens SENTRON 5SV6316-7KK16 AFDD-RCBO, 230 V AC, 16 A, 6 kA, Type A, 30 mA, DIN rail. Active production, sourced to order. Quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68.5 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","protection class IP":"IP20, with connected protective device and conductors","Overvoltage Category":"III","Design Of The Product":"Compact unit","Residual Current Type":"A","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"any","Tripping Characteristic Class":"C","Tripping Fault Current Rated Value":"30 mA","according to EN 60898-1 rated value":"6 000 A","according to IEC 60947-2 rated value":"6 000 A","Switching Function Short-Term Delayed":"No","operational current at AC rated value":"16 A","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50Hz","Ambient Temperature With Relative Humidity 95%":"55 °C","Mechanical Service Life (Switching Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","In The Event Of Electrical Arcs In Series With The Load Maximum":"16 A","In The Event Of Electrical Arcs In Series With The Load Minimum":"2 A","In The Event Of Electrical Arcs In Parallel With The Load Maximum":"500 A","In The Event Of Electrical Arcs In Parallel With The Load Minimum":"50 A","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.81 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1108736&mlfb=5SV6316-7KK16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV6316-7KK16/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 5SV6316-7KK16 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and delivery window."},{"question":"What is the difference between 5SV6316-7KK16 and 5SY4116-7CV?","answer":"The 5SV6316-7KK16 is an AFDD-RCBO combining arc-fault detection, overcurrent, and residual-current protection in one unit. The 5SY4116-7CV is a standard MCB only — no residual-current or arc-fault function. They are not drop-in substitutes; the 5SV6316-7KK16 replaces a separate MCB + RCCD + AFDD combination in the same panel width."},{"question":"What compliance documentation is available for 5SV6316-7KK16?","answer":"The part carries IEC/EN 62606 (AFDD), IEC 60898-1 and IEC 60947-2 (MCB/RCBO) compliance. As a Siemens SENTRON product, RoHS, REACH, and CE declarations are standard. No UL listing is claimed on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV6316-7KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV6316-7KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}