{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9313-7CR25","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9313-7CR25","canonicalUrl":"https://aoctrl.com/siemens/5SV9313-7CR25","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9313-7CR25","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9313-7CR25, RCBO, 2-pole, 25 A rated, 30 mA residual current, Type A, tripping characteristic C, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), 1 MW, halogen-free, IP20.","salesMarkdown":"It is rated 25 A at AC with a 30 mA residual fault current trip, Type A (pulsating DC and AC sensitive), tripping characteristic C. The unit occupies one modular width on a DIN rail, saving panel space compared to separate MCB + RCCD combinations. Rated breaking capacity is 4.5 kA per EN 60898 and 5 kA per IEC 60947-2, with overvoltage category III and pollution degree 2 — suitable for final circuits in residential and commercial distribution boards. The 25 A rating at 30 °C derates to 23.75 A at 40 °C, 23 A at 45 °C, 22.25 A at 50 °C, and 21.5 A at 55 °C. If your panel ambient runs above 30 °C, size the load accordingly — a 25 A circuit at 50 °C can only carry 22.25 A continuously without nuisance tripping. The 30 mA residual current trip, Type A, covers sinusoidal AC faults and pulsating DC faults up to 6 mA smooth DC — the standard for general socket-outlet circuits and most single-phase equipment. The instantaneous design (no intentional delay) trips within 40 ms at rated fault current, which meets the disconnection times in IEC 60364 for TN and TT systems. For high-inrush loads (large transformers, motor starters), characteristic D would be a better fit. Snap-on DIN rail mount, 1 MW (18 mm wide), 77 mm depth, 90 mm height. Installation depth is 70 mm — verify your enclosure depth clears this. Touch protection is provided on the terminals. Mount in a clean, dry enclosure.","metaTitle":"Siemens 5SV9313-7CR25 SENTRON RCBO, 25 A, 30 mA, Type A, 2-p","metaDescription":"Siemens 5SV9313-7CR25 SENTRON RCBO, 25 A rated, 30 mA residual current, Type A, 2-pole, 4.5 kA (EN 60898), 5 kA (IEC 60947-2), 1 MW, halogen-free, current lifecycle stage, availabl","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV9313-7CR25","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO, Icn: 4.5 kA, 1P+N, type A, 30 mA, C-Char, In: 25 A, Un AC: 230 V, compact, China retail line","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"25 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"135 g","at 30 °C / rated value":"25 A","at 40 °C / rated value":"23.75 A","at 45 °C / rated value":"23 A","at 50 °C / rated value":"22.25 A","at 55 °C / rated value":"21.5 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"5 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629443&mlfb=5SV9313-7CR25"},"ai":{"faq":[{"question":"What is 5SV9313-7CR25's rated breaking capacity?","answer":"4.5 kA per EN 60898 and 5 kA per IEC 60947-2, at the rated voltage."},{"question":"What is the temperature derating for 5SV9313-7CR25?","answer":"Rated 25 A at 30 °C, derated to 23.75 A at 40 °C, 23 A at 45 °C, 22.25 A at 50 °C, and 21.5 A at 55 °C."},{"question":"Where can I buy 5SV9313-7CR25 and how is it quoted?","answer":"This RCBO is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, no stock figures on the page."},{"question":"Will 5SV9313-7CR25 drop into a panel specified around 5SL6016-7KL?","answer":"Both are 1-MW DIN-rail RCBOs from the SENTRON family, but the 5SV9313-7CR25 is a 2-pole Type A unit (25 A, 30 mA), while the 5SL6016-7KL is a different variant. Verify the pole count, residual current type, and tripping characteristic before substituting — the physical footprint is the same, but the electrical function may differ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9313-7CR25","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9313-7CR25 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}