{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9313-7NK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9313-7NK06","canonicalUrl":"https://aoctrl.com/siemens/5SV9313-7NK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9313-7NK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9313-7NK06, RCD-operated circuit breaker (RCBO), 6 A rated at AC, Type A, 30 mA, 1P+N, tripping characteristic C, 4.5 kA SCCR, instantaneous design, 18 mm width, 77 mm depth.","salesMarkdown":"The Siemens SENTRON 5SV9313-7NK06 is a 2-pole (1P+N) RCD-operated circuit breaker — an RCBO — combining overcurrent and residual-current protection in a single 18 mm-wide module. Rated 6 A at AC with tripping characteristic C and Type A residual-current sensitivity, it breaks fault currents up to 4.5 kA. The instantaneous design clears short-circuits fast. ## Ratings and thermal derating Above that, the continuous current must be derated: 5.64 A at 40 °C, 5.46 A at 45 °C, 5.22 A at 50 °C, and 5.04 A at 55 °C. Ambient operating range is -25 to +40 °C; storage range is -40 to +75 °C. Mounting position is unrestricted, so it fits horizontal or vertical DIN-rail layouts without further derating. ## Installation and wiring The module occupies one width unit (18 mm) on a DIN rail, with an installation depth of 70 mm and overall depth of 77 mm. Terminals accept solid or stranded conductors from 0.75 to 16 mm². Supply can enter from either top or bottom, simplifying panel layout. Touch protection is built in. The IP20 rating applies only when the distribution board is installed and conductors are connected — not a standalone ingress rating.","metaTitle":"Siemens SENTRON 5SV9313-7NK06 RCBO, 6 A, Type A, 30 mA, 1P+N","metaDescription":"Siemens SENTRON 5SV9313-7NK06 RCD-operated circuit breaker, 6 A rated at AC, Type A, 30 mA, 1P+N, 4.5 kA SCCR. Quoted to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Solid":"0.75 ... 16 mm²","Width":"18 mm","title":"5SV9313-7NK06","Height":"90 mm","Maximum":"1.5 W","Stranded":"0.75 ... 16 mm²","at 30 Cel":"6 A","at 40 Cel":"5.64 A","at 45 Cel":"5.46 A","at 50 Cel":"5.22 A","at 55 Cel":"5.04 A","description":"RCBO, Icn: 4.5 kA, 1P+N, type A, 30 mA, C-Char, In: 6 A, Un AC: 230 V, compact","Halogen-Free":"Yes","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"2","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +40 °C","Product designation":"RCD-operated circuit breaker","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Energy limiting class":"3","Number of width units":"1","Type of fault current":"A","Number of poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SV9","Current / at AC / rated value":"6 A","Tripping characteristic class":"C","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / of power supply cord":"Either top or bottom","Number of poles / with protection":"1","acc. to IEC 60947-2 / rated value":"4.5 kA","Product feature / Touch protection":"Yes","Supply voltage frequency / rated value":"50 Hz","Tripping residual current / rated value":"30 mA","Influence of the surrounding temperature":"Max. 95% humidity","Surge current resistance / at (8/20) μs":"1 kA","Tightening torque / with screw-type terminals":"1.2 ... 2 N·m","Product function / neutral conductor switching":"Yes","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629445&mlfb=5SV9313-7NK06"},"ai":{"faq":[{"question":"What is the depth of 5SV9313-7NK06?","answer":"77 mm overall depth; installation depth is 70 mm."},{"question":"What conductor sizes does 5SV9313-7NK06 accept?","answer":"Solid or stranded conductors from 0.75 to 16 mm²."},{"question":"Will 5SV9313-7NK06 drop into a panel designed for 5SL6563-7BB without rewiring?","answer":"Both are 18 mm-wide 1P+N RCBOs on the same DIN-rail footprint, but the 5SL6563-7BB is a different series with different terminal layout and tripping characteristics — verify terminal positions and wiring diagram before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9313-7NK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9313-7NK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}