{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-0PK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-0PK06","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-0PK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-0PK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9 series, RCD-operated circuit breaker (RCBO), 1P+N, 6 A, B characteristic, 6 kA, 230/240 V AC, 50/60 Hz.","salesMarkdown":"## Integrator note — 5SV9316-0PK06 The Siemens 5SV9316-0PK06 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON 5SV9 series, combining overcurrent protection and residual current detection in a single 18 mm wide module. Rated 6 A with a B tripping characteristic, it breaks fault currents up to 6 kA per both EN 60898 and IEC 60947-2 at 230/240 V AC, 50/60 Hz. The instantaneous design means no intentional delay on the RCD side — trips when leakage exceeds the threshold. Supply connects from below; touch protection is built in. At 40 °C it derates to 5.64 A, at 45 °C to 5.46 A, at 50 °C to 5.22 A, and at 55 °C to 5.04 A. ## Panel fit and compliance Occupies one width unit (18 mm) on the DIN rail. Silicon-free construction, which matters for potting or conformal coating processes.","metaTitle":"Siemens 5SV9316-0PK06 SENTRON RCD/RCBO, 6 A, B Curve, 6 kA","metaDescription":"Siemens 5SV9316-0PK06 SENTRON RCD-operated circuit breaker, 6 A rated, B tripping characteristic, 6 kA breaking capacity per EN 60898/IEC 60947-2. Current lifecycle stage. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","at 30 Cel":"6 A","at 40 Cel":"5.64 A","at 45 Cel":"5.46 A","at 50 Cel":"5.22 A","at 55 Cel":"5.04 A","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree of pollution":"2","Operating frequency":"50/60 Hz","Product designation":"RCD-operated circuit breaker","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","at AC / rated value":"230/240 V","Overvoltage Category":"III","Design of the product":"Instantaneous","Energy limiting class":"3","Number Of Width Units":"1","Type of fault current":"AC","Number of poles / Note":"1P+N","circuit-breaker / Design":"5SV9","power loss [W] / maximum":"2.94 W","Tripping characteristic class":"B","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / of power supply cord":"from below","Number of poles / with protection":"1","acc. to IEC 60947-2 / rated value":"6 kA","Product feature / Touch protection":"Yes","Supply voltage frequency / rated value":"50 Hz","Operating current / at AC / rated value":"6 A","Reference code / acc. to DIN EN 81346-2":"F","Tripping residual current / rated value":"30 mA","reference code / acc. to DIN EN 61346-2":"F","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge current resistance / at (8/20) μs":"1 kA","Product function / neutral conductor switching":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=695063&mlfb=5SV9316-0PK06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV9316-0PK06/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV9316-0PK06?","answer":"Submit an RFQ through this listing. We source the 5SV9316-0PK06 to order and confirm current pricing and availability at quote time."},{"question":"What is 5SV9316-0PK06's listed depth (77 mm) on this component line?","answer":"The 5SV9316-0PK06 has a depth of 77 mm and an installation depth of 70 mm, fitting standard distribution boards."},{"question":"What is 5SV9316-0PK06's listed width (18 mm) on this component line?","answer":"The 5SV9316-0PK06 is 18 mm wide, occupying one width unit on the DIN rail."},{"question":"What compliance documentation does this brand provide for 5SV9316-0PK06 (RoHS, REACH, UL, IEC)?","answer":"The 5SV9316-0PK06 carries ratings per EN 60898 and IEC 60947-2 for breaking capacity. Touch protection is built in. The manufacturer typically provides RoHS and REACH declarations; confirm specific documentation needs at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-0PK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-0PK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}