{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-0PK40","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-0PK40","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-0PK40","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-0PK40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9316-0PK40 RCD-operated circuit breaker, 40 A, 6 kA, Type B, 1P+N, 50 Hz, 18 mm width.","salesMarkdown":"The Siemens 5SV9316-0PK40 is a SENTRON RCD-operated circuit breaker — an RCBO combining overcurrent and residual current protection in a single 18 mm-wide module. Rated 40 A at 50 Hz with a Type B tripping characteristic, it clears faults up to 6 kA per EN 60898 and IEC 60947-2. The 1P+N configuration protects one live conductor while switching the neutral, common in single-phase final subcircuits where you want both poles isolated on a fault. The 40 A rating is the continuous current at 30 °C ambient; it derates to 38 A at 40 °C and 36 A at 50 °C, so if your panel runs hot, factor that in. Type B trips at 3–5× rated current, meaning it handles modest inrush from resistive and small motor loads but will nuisance-trip on high-starting-current equipment — that's the right call for general-purpose socket circuits and lighting, not for large drives or transformers. It detects AC-type residual currents only — sinusoidal AC earth faults. That covers most general wiring, but if your loads include variable-speed drives, UPS systems, or switched-mode power supplies that generate pulsed or DC fault currents, you need a Type A or Type B RCD instead. Snaps onto a standard 35 mm DIN rail, occupies one width unit (18 mm), and accepts solid or stranded conductors from 0.75 mm² up to 16 mm² — enough for the 40 A feed. The supply connects from below per the datasheet. Depth is 77 mm, installation depth 70 mm, so it clears most shallow enclosures. IP20 with the distribution board installed and conductors connected — it's not a standalone outdoor device. Mounting position is any, which helps in tight panels. Power dissipation maxes at 9.68 W — not negligible if you pack a dozen of these in a sealed enclosure; account for the heat.","metaTitle":"Siemens 5SV9316-0PK40 SENTRON RCD Circuit Breaker, 40 A, 6 k","metaDescription":"Siemens 5SV9316-0PK40 SENTRON RCD-operated circuit breaker, 40 A rated, 6 kA breaking capacity, Type B characteristic, 1P+N, 50 Hz. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Solid":"0.75 ... 16 mm²","Width":"18 mm","title":"5SV9316-0PK40","Height":"90 mm","Maximum":"9.68 W","Stranded":"0.75 ... 16 mm²","at 30 Cel":"40 A","at 40 Cel":"38 A","at 45 Cel":"36.8 A","at 50 Cel":"36 A","at 55 Cel":"34.8 A","description":"RCBO, Icn: 6 kA, 1P+N, Type AC, 30 mA, B char., In: 40 A, Un AC: 240 V, pigtail 600 mm","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"2","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +55 °C","Product designation":"RCD-operated circuit breaker","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Energy limiting class":"3","Number of width units":"1","Type of fault current":"AC","Number of poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SV9","Current / at AC / rated value":"40 A","Tripping characteristic class":"B","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / of power supply cord":"from below","Number of poles / with protection":"1","acc. to IEC 60947-2 / rated value":"6 kA","Product feature / Touch protection":"Yes","Supply voltage frequency / rated value":"50 Hz","Tripping residual current / rated value":"30 mA","Influence of the surrounding temperature":"Max. 95% humidity","Surge current resistance / at (8/20) μs":"1 kA","Tightening torque / with screw-type terminals":"1.2 ... 2 N·m","Product function / neutral conductor switching":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=695068&mlfb=5SV9316-0PK40"},"ai":{"faq":[{"question":"What is the breaking capacity of this RCBO?","answer":"6 kA per both EN 60898 and IEC 60947-2 — sufficient for most final subcircuits in domestic and light commercial panels."},{"question":"What type of residual current does the 5SV9316-0PK40 detect?","answer":"AC type only — sinusoidal AC earth faults. Not suitable for pulsed or DC fault currents from VFDs or UPS systems."},{"question":"Where can I buy the 5SV9316-0PK40?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-0PK40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-0PK40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}