{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-1PK20","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-1PK20","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-1PK20","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-1PK20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9 series, RCD-operated circuit breaker, 2-pole 1P+N, 20 A rated, C tripping characteristic, 6 kA breaking capacity per EN 60898, 50 Hz, IP20, 18 mm width.","salesMarkdown":"The Siemens 5SV9316-1PK20 is a SENTRON 5SV9 series RCD-operated circuit breaker — an RCBO that combines overcurrent protection and residual current detection in a single 18 mm wide, 2-pole (1P+N) package. It's rated 20 A at 50 Hz with a C tripping characteristic, meaning it handles moderate inrush from motor or lighting loads without nuisance tripping, and breaks faults up to 6 kA per EN 60898 and IEC 60947-2. The 20 A rating is at 30 °C ambient; derate to 19 A at 40 °C, 18 A at 50 °C, and 17.4 A at 55 °C — the thermal curve matters if this lands in a crowded enclosure or near a heat source. Width is 18 mm (1 width unit), depth 77 mm with 70 mm installation depth. Mounts in any position on DIN rail. Touch protection is built in; IP20 rating assumes the distribution board is installed with conductors connected. Supply feeds from below per the design.","metaTitle":"Siemens 5SV9316-1PK20 SENTRON RCD Circuit Breaker, 20 A C-cu","metaDescription":"Siemens 5SV9316-1PK20 SENTRON 2-pole RCD-operated circuit breaker, 20 A rated, C characteristic, 6 kA breaking capacity per EN 60898. Current production. Available to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Solid":"0.75 ... 16 mm²","Width":"18 mm","title":"5SV9316-1PK20","Height":"90 mm","Maximum":"6.02 W","Stranded":"0.75 ... 16 mm²","at 30 Cel":"20 A","at 40 Cel":"19 A","at 45 Cel":"18.4 A","at 50 Cel":"18 A","at 55 Cel":"17.4 A","description":"RCBO, Icn: 6 kA, 1P+N, Type AC, 30 mA, C-Char, In: 20 A, Un AC: 240 V, pigtail 600 mm","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"2","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +55 °C","Product designation":"RCD-operated circuit breaker","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Energy limiting class":"3","Number of width units":"1","Type of fault current":"AC","Number of poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SV9","Current / at AC / rated value":"20 A","Tripping characteristic class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / of power supply cord":"from below","Number of poles / with protection":"1","acc. to IEC 60947-2 / rated value":"6 kA","Product feature / Touch protection":"Yes","Supply voltage frequency / rated value":"50 Hz","Tripping residual current / rated value":"30 mA","Influence of the surrounding temperature":"Max. 95% humidity","Surge current resistance / at (8/20) μs":"1 kA","Tightening torque / with screw-type terminals":"1.2 ... 2 N·m","Product function / neutral conductor switching":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=695072&mlfb=5SV9316-1PK20"},"ai":{"faq":[{"question":"Where can I buy 5SV9316-1PK20 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent industrial distribution. Submit an RFQ for current availability and pricing — no stock count or price is published here."},{"question":"What is 5SV9316-1PK20's listed depth?","answer":"Depth is 77 mm, with an installation depth of 70 mm. Width is 18 mm (1 width unit), height 90 mm."},{"question":"What conductor sizes does 5SV9316-1PK20 accept?","answer":"Solid and stranded conductors from 0.75 to 16 mm² — covers most branch circuit wiring down to 4 AWG."},{"question":"What is the breaking capacity of 5SV9316-1PK20?","answer":"6 kA rated per both EN 60898 and IEC 60947-2, which covers typical commercial and light industrial panelboard fault levels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-1PK20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-1PK20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}