{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-1PK32","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-1PK32","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-1PK32","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-1PK32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9316-1PK32, RCD-operated circuit breaker, 1P+N, 32 A, 30 mA, Type AC, Tripping characteristic C, 6 kA, 77x18x90 mm.","salesMarkdown":"The Siemens 5SV9316-1PK32 is a SENTRON RCBO — a combined RCD and MCB in one 18 mm wide module, protecting a single-phase final circuit against overload, short-circuit, and earth leakage. Single modular-width unit (18 mm) snaps onto standard DIN rail. Depth is 77 mm, installation depth 70 mm — fits flush in most 80 mm deep enclosures. Supply feeds from below; any mounting position allowed. IP20 only once the distribution board is installed and conductors connected, so it's not a standalone outdoor device. ## Thermal derating and environment Rated 32 A at 30 °C, but derates to 30.4 A at 40 °C, 29.44 A at 45 °C, 28.8 A at 50 °C, and 27.84 A at 55 °C. If your panel runs warm, size the upstream breaker accordingly. Silicon-free construction matters for automotive or paint-line environments where silicone outgassing causes adhesion failures.","metaTitle":"Siemens 5SV9316-1PK32 SENTRON RCBO, 32 A, 30 mA, Type AC, C-","metaDescription":"Siemens 5SV9316-1PK32 SENTRON RCD-operated circuit breaker, 1P+N, 32 A, 30 mA residual current, Type AC, C-curve, 6 kA breaking capacity, 77x18x90 mm. Current lifecycle. Sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV9316-1PK32","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO, Icn: 6 kA, 1P+N, Type AC, 30 mA, C-Char, In: 32 A, Un AC: 240 V, pigtail 600 mm","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"32 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Weight With Packaging":"155 g","at 30 °C rated value":"32 A","at 40 °C rated value":"30.4 A","at 45 °C rated value":"29.44 A","at 50 °C rated value":"28.8 A","at 55 °C rated value":"27.84 A","Energy Limitation Class":"3","according to EN 61346-2":"F","according to IEC 81346-2":"F","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"from below","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","Tripping Fault Current Rated Value":"30 mA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"6 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","for rated value of the current at AC in hot operating state per pole":"3.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=695073&mlfb=5SV9316-1PK32"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV9316-1PK32?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is 5SV9316-1PK32's listed depth?","answer":"77 mm overall depth, with a 70 mm installation depth behind the panel face."},{"question":"What is 5SV9316-1PK32's width?","answer":"18 mm — one modular width unit on standard DIN rail."},{"question":"Will 5SV9316-1PK32 drop into a panel specified around 5SL4106-7CC without rewiring?","answer":"Not directly — the 5SL4106-7CC is a standard MCB without residual-current protection, while the 5SV9316-1PK32 is an RCBO. The footprint (18 mm width, DIN rail) is the same, but the wiring and circuit protection function differ. Verify the circuit's earth-leakage requirements before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-1PK32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-1PK32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}