{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-6NK25","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-6NK25","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-6NK25","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-6NK25","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV9316-6NK25 RCBO, 2-pole, 25 A, 30 mA, Type A, 6 kA, 1 MW, IP20.","salesMarkdown":"The 25 A rated current (at 30 °C, per) and B-curve tripping characteristic mean this RCBO is sized for general-purpose loads with modest inrush — lighting, small appliances, and socket circuits. Type A is the minimum requirement under IEC 60364 for circuits supplying single-phase rectified equipment. The supply connection can be made from either the top or bottom. Depth is 77 mm (70 mm installation depth), which clears most standard enclosure backplates. IP20 rated with conductors connected, so it is intended for enclosed panel use. Ambient temperature range spans -40 °C to +75 °C, with rated current derating applied above 30 °C: 0.95 A at 40 °C, 0.93 A at 45 °C, 0.9 A at 50 °C, 0.87 A at 55 °C. This derating curve is critical for panel builders when grouping multiple RCBOs in a confined space — thermal accumulation can reduce the effective rating below the marked 25 A.","metaTitle":"Siemens 5SV9316-6NK25 SENTRON RCBO, 25 A, 30 mA, Type A, 6 k","metaDescription":"Siemens SENTRON 5SV9316-6NK25 RCBO, 25 A rated, 30 mA residual current, Type A, 6 kA breaking capacity (EN 60898). Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV9316-6NK25","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO, Icn: 6 kA, 1P+N, type A, 30 mA, B-Char, In: 25 A, Un AC: 240 V, compact","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"25 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"135 g","at 30 °C / rated value":"25 A","at 40 °C / rated value":"0.95 A","at 45 °C / rated value":"0.93 A","at 50 °C / rated value":"0.9 A","at 55 °C / rated value":"0.87 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"6 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1399069&mlfb=5SV9316-6NK25"},"ai":{"faq":[{"question":"What is 5SV9316-6NK25's listed depth (77 mm) on this component line?","answer":"The total depth is 77 mm; installation depth (into the panel) is 70 mm. This clears most standard enclosure backplates and leaves clearance for wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-6NK25","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-6NK25 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}