{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-6PK10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-6PK10","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-6PK10","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-6PK10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 5SV9316-6PK10, 10A rated, B-curve, 30mA residual current, 6kA breaking capacity, 1P+N, 1 MW wide.","salesMarkdown":"The Siemens 5SV9316-6PK10 is a SENTRON RCBO — a combined RCD and MCB in one 1-module-wide (18 mm) package. It provides overcurrent protection (B-curve, 10 A rated) and residual current protection (30 mA, Type A) in a single device, saving DIN-rail space in final distribution boards. The 30 mA trip threshold covers personnel protection against direct contact. The 10 A rating at 30 °C derates to 9.4 A at 40 °C and 8.4 A at 55 °C — if your panel ambient runs hot, factor that in. The B-curve (3–5 In) means it holds short-duration inrush from resistive and lighting loads but trips fast on a hard fault. Type A residual current detection handles pulsating DC fault waveforms from single-phase rectified loads (SMPS, LED drivers, appliances). The 1P+N form factor switches the line and monitors the neutral; the neutral is not switched. Width is 18 mm (1 MW), depth 77 mm, height 90 mm. Installation depth 70 mm — ensure the enclosure has enough clearance behind the DIN rail. Rated for ambient -40 °C to 75 °C and up to 95% humidity. Silicon-free construction is noted for applications sensitive to outgassing.","metaTitle":"Siemens 5SV9316-6PK10 SENTRON RCBO, 10A B-curve 30mA 6kA 1P+","metaDescription":"Siemens 5SV9316-6PK10 SENTRON RCBO, 10A rated, B-curve, 30mA residual current, 6kA breaking capacity per EN 60898. 1P+N, 1 MW wide. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"10 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"155 g","at 30 °C / rated value":"10 A","at 40 °C / rated value":"9.4 A","at 45 °C / rated value":"9.1 A","at 50 °C / rated value":"8.7 A","at 55 °C / rated value":"8.4 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"from below","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"6 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Product Function / Neutral Conductor Switching":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=695076&mlfb=5SV9316-6PK10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV9316-6PK10/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV9316-6PK10 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is 5SV9316-6PK10's listed depth (77 mm) on this component line?","answer":"The listed depth is 77 mm, with an installation depth of 70 mm."},{"question":"What is 5SV9316-6PK10's listed width (18 mm) on this component line?","answer":"The width is 18 mm, which is 1 modular width unit (1 MW)."},{"question":"What compliance documentation does this brand provide for 5SV9316-6PK10 (RoHS, REACH, UL, IEC)?","answer":"The part is rated per EN 60898 and IEC 60947-2. The evidence does not list RoHS, REACH, or UL documentation specifically; these are typically available from the manufacturer's product page or upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-6PK10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-6PK10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}