{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV9316-7PK10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV9316-7PK10","canonicalUrl":"https://aoctrl.com/siemens/5SV9316-7PK10","factsUrl":"https://aoctrl.com/api/mcp/products/5SV9316-7PK10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 10 A, 30 mA, Type A, 6 kA, 1 MW, 18 mm wide.","salesMarkdown":"The Siemens SENTRON 5SV9316-7PK10 is an RCD-operated circuit breaker (RCBO) combining overcurrent protection and residual current detection in a single 18 mm wide module (1 MW). It protects a single-phase final subcircuit at 10 A rated current with a 30 mA residual-current trip threshold, Type A (sensitive to pulsating DC and AC sinusoidal fault currents). Tripping characteristic C means it holds 5–10× In for short magnetic trips — suited to mixed resistive and moderate motor-start loads. Above that, derate linearly: 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.4 A at 55 °C. If the panel runs warm — say 45 °C inside the enclosure — the continuous load must stay under 9.1 A to avoid nuisance tripping. The device is silicon-free, which matters in clean-room or potting-sensitive applications. The 18 mm width (1 MW) leaves room for other modules in a compact sub-distribution board. Supply feeds from below. The IP20 rating applies only when the distribution board is installed with connected conductors — not a standalone outdoor part.","metaTitle":"Siemens SENTRON 5SV9316-7PK10 RCBO, 10 A, 30 mA, Type A, 6 k","metaDescription":"Siemens SENTRON 5SV9316-7PK10 RCBO, 10 A rated, 30 mA residual current, Type A, 6 kA breaking capacity (EN 60898 / IEC 60947-2). Current production. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","at AC / rated value":"10 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Energy Limitation Class":"3","Weight / With Packaging":"155 g","according to EN 61346-2":"F","at 30 °C / rated value":"10 A","at 40 °C / rated value":"9.4 A","at 45 °C / rated value":"9.1 A","at 50 °C / rated value":"8.7 A","at 55 °C / rated value":"8.4 A","according to IEC 81346-2":"F","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"from below","Number Of Poles / With Protection":"1","according to EN 60898 / rated value":"6 kA","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","according to IEC 60947-2 / rated value":"6 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05db08bf17e53a37e5c485dcffc27c74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=695082&mlfb=5SV9316-7PK10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV9316-7PK10/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the 5SV9316-7PK10?","answer":"6 kA per both EN 60898 and IEC 60947-2, which covers final subcircuits in domestic and light commercial panels."},{"question":"What is the residual current rating and type?","answer":"30 mA, Type A — detects AC sinusoidal and pulsating DC fault currents, the standard for socket-outlet circuits in most IEC-based installations."},{"question":"Where can I buy the 5SV9316-7PK10?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation is available for the 5SV9316-7PK10?","answer":"The part carries approvals per EN 60898 and IEC 60947-2. RoHS and REACH compliance documentation is typically provided by the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV9316-7PK10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV9316-7PK10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}