{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4106-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4106-7","canonicalUrl":"https://aoctrl.com/siemens/5SY4106-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4106-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4106-7, 1-pole miniature circuit breaker, C-curve, 6 A rated, 10 kA breaking capacity per IEC/EN 60898-1, 35 kA per IEC 60947-2, 18 mm width.","salesMarkdown":"Breaking capacity is the headline number here: 10 kA under IEC/EN 60898-1 for general distribution, 35 kA under IEC 60947-2 for industrial feeder duty, and 15 kA at DC per the same standard. Approvals include IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No. 235 (5 kA at AC). Halogen-free and silicon-free construction, sealable terminals, and IP20 with conductors connected — so it meets the material compliance and ingress requirements for most panel builds. ## Panel fit & integration Mounts in any position via the quick-assembly system (standard DIN rail). Combined top and bottom terminals simplify daisy-chaining, and the supply cord position is unrestricted. Rated operating temperature spans -40 °C to 75 °C, with humidity derating above 55 °C (95% RH up to 55 °C, 55% up to 70 °C, 35% up to 75 °C). Suitable for mechanical engineering and industrial environments as stated in the suitability field.","metaTitle":"Siemens 5SY4106-7 SENTRON MCB, 1P C-curve 6A, 10kA IEC 60898","metaDescription":"Siemens 5SY4106-7 SENTRON miniature circuit breaker, 1-pole, C-curve, 6A. Breaking capacity 10 kA per IEC 60898, 35 kA per IEC 60947-2. Active production, sourced to order. Request","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY4106-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 230/400 V 10kA, 1-pole, C, 6 A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"10 kA","according to IEC 60947-2 rated value":"35 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$8.38","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b9fd441a547e09d75775bd30a3d81223.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=390588&mlfb=5SY4106-7"},"ai":{"faq":[{"question":"Where can I buy 5SY4106-7 and get a price?","answer":"The 5SY4106-7 is available to order against an RFQ through independent distribution. Current pricing and lead time are confirmed at quote — submit a request for a firm quote."},{"question":"What is the breaking capacity of 5SY4106-7?","answer":"10 kA per IEC/EN 60898-1, 35 kA per IEC 60947-2 at 400 V AC, and 15 kA at DC per IEC 60947-2. Under UL 1077 it is rated 5 kA at AC."},{"question":"What compliance documentation does Siemens provide for 5SY4106-7?","answer":"The breaker carries approvals to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No. 235. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity and material compliance data."},{"question":"Will 5SY4106-7 drop into a panel specified around 5SY4140-7?","answer":"Yes — both are 1-pole SENTRON MCBs in the same 18 mm footprint with identical depth and mounting. The difference is the current rating: 5SY4106-7 is 6 A, while 5SY4140-7 is 40 A. No rewiring or panel modification is needed if the ampacity matches the circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4106-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4106-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}