{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4116-6CC11","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4116-6CC11","canonicalUrl":"https://aoctrl.com/siemens/5SY4116-6CC11","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4116-6CC11","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4116-6CC11, 1-pole miniature circuit breaker, B-curve, 16 A rated current, 10 kA breaking capacity at 400 V AC, 18 mm width, IP20.","salesMarkdown":"The Siemens 5SY4116-6CC11 is a 1-pole SENTRON miniature circuit breaker (MCB) with a B tripping characteristic, rated at 16 A and 400 V AC, with a 10 kA breaking capacity per EN 60898. Terminals accept solid or stranded conductors from 0.75 to 35 mm², torqued to 2.5–3.5 N·m. Combined top and bottom terminals simplify daisy-chaining busbars. Rated 16 A at 400 V AC, B-curve — the breaker holds 16 A continuously and trips magnetically between 48 and 80 A. Energy limiting class 3 keeps let-through energy low, reducing stress on downstream components. Maximum DC voltage is 72 V — usable for DC auxiliary circuits within that limit, but not for 125 V DC rails. No neutral pole switching (1P only). Sealable terminals allow tamper-proofing after commissioning. Designed for railway applications and mechanical engineering / industry. Suitable for any mounting position.","metaTitle":"Siemens 5SY4116-6CC11 SENTRON MCB, 1P B 16 A 10 kA, 400 V","metaDescription":"Siemens SENTRON 5SY4116-6CC11 miniature circuit breaker, 1-pole, B-curve, 16 A, 10 kA breaking capacity at 400 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Solid":"0.75 ... 35 mm²","Width":"18 mm","title":"5SY4116-6CC11","Height":"90 mm","Sealable":"Yes","Stranded":"0.75 ... 35 mm²","Rated Value":"50/60 Hz","description":"Miniature circuit breaker 230/400 V 10kA, 1-pole, B, 16A for railway applications","Halogen-Free":"Yes","Silicon-Free":"Yes","Mounting type":"Quick assembly system","During Storage":"-40 ... +75 °C","Number of poles":"1","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-40 ... +70 °C","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","at AC / rated value":"400 V","Overvoltage category":"III","Combined Terminal Top":"Yes","Design of the product":"For railway applications","Energy limiting class":"3","Number of width units":"1","Number of poles / Note":"1P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","Combined Terminal Bottom":"Yes","Suitability for operation":"Mechanical engineering / industry","Current / at AC / rated value":"16 A","Tripping characteristic class":"B","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"10 kA","Position / of power supply cord":"Any","Product feature / Touch protection":"Yes","Influence of the surrounding temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Tightening torque / with screw-type terminals":"2.5 ... 3.5 N·m","Product function / neutral conductor switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"440 V","Mechanical service life (switching cycles) / typical":"10 000","Tightening torque [lbf·in] / with screw-type terminals":"22 ... 31 lbf·in"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9d523dc8fff8ccf3fb7ac22b0f10b574.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=443710&mlfb=5SY4116-6CC11"},"ai":{"faq":[{"question":"Where can I buy 5SY4116-6CC11 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the depth of 5SY4116-6CC11?","answer":"The depth is 76 mm, with an installation depth of 70 mm."},{"question":"What conductor sizes does 5SY4116-6CC11 accept?","answer":"Solid and stranded conductors from 0.75 to 35 mm², torqued to 2.5–3.5 N·m."},{"question":"Will 5SY4116-6CC11 drop into a panel specified for 5SY3132-6 without rewiring?","answer":"Both are 1-pole SENTRON MCBs on the same DIN-rail footprint (18 mm width), so mechanical fit is identical. The 5SY4116-6CC11 is a 16 A B-curve; the 5SY3132-6 is a different rating and curve — verify the load current and tripping characteristic before substitution."},{"question":"What compliance documentation does Siemens provide for 5SY4116-6CC11?","answer":"The MCB carries EN 60898 certification for breaking capacity. The halogen-free and silicon-free construction supports RoHS/REACH compliance typically, but specific declarations should be requested at order time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4116-6CC11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4116-6CC11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}