{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4213-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4213-7","canonicalUrl":"https://aoctrl.com/siemens/5SY4213-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4213-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 2-pole, C-curve, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 400 V AC, 5SY4213-7.","salesMarkdown":"The Siemens 5SY4213-7 is a 2-pole miniature circuit breaker from the SENTRON family, built to IEC / EN 60898-1 and IEC / EN 60947-2 / UL1077 standards. It snaps onto a DIN rail — any mounting position works — and takes up two modular width units (36 mm wide, 76 mm deep, 90 mm tall). Rated 400 V AC (440 V max in multi- or single-phase operation) and 60 V DC (72 V max), with a C tripping curve that handles moderate inrush from motor starters and lighting ballasts. The 10 kA breaking capacity per EN 60898 covers most commercial panel faults; the 20 kA rating per IEC 60947-2 gives headroom for industrial distribution where fault currents run higher. DC-side breaking is 15 kA per IEC 60947-2, and UL 1077 listing is 5 kA for North American panels. Compliance documentation covers IEC/EN 60898-1, IEC/EN 60947-2, and UL1077. The breaker is halogen-free and silicon-free, rated for pollution degree 3 and overvoltage category III, with an IP20 enclosure (IP20 with conductors connected). The C-curve (tripping characteristic C) means it holds through 5–10× rated current for short-duration inrush — typical for motor starters, small transformers, and capacitor banks. If your load is purely resistive (heaters, incandescent lighting), a B-curve would trip faster; if it's heavy inductive (large motors, welding gear), a D-curve might be needed. This one splits the difference for general industrial and commercial panels. Temperature range is -40 °C to 75 °C, with humidity derating above 55 °C (max 95% RH at 55 °C, dropping to 35% at 75 °C).","metaTitle":"Siemens 5SY4213-7 SENTRON MCB, C-Curve 2-Pole 10kA","metaDescription":"Siemens 5SY4213-7 SENTRON 2-pole MCB, C-curve, 10 kA per EN 60898, 20 kA per IEC 60947-2. Rated 400 V AC. Current production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"2","Width":"36 mm","Height":"90 mm","Mounting":"Quick assembly system","IP Rating":"IP20","Product Status":"Active","Temp Operating Max":"75 °C","Temp Operating Min":"55 °C","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$19.05","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d31c0e3df8658ef64c5e8f10d775ea9c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=204239&mlfb=5SY4213-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SY4213-7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4213-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4213-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}